Smoothing Intermittent Output Power in Grid-Connected Doubly Fed Induction Generator Wind Turbines with Li-Ion Batteries
Author:
Behabtu Henok Ayele12ORCID, Vafaeipour Majid1ORCID, Kebede Abraham Alem2, Berecibar Maitane1, Van Mierlo Joeri1ORCID, Fante Kinde Anlay2ORCID, Messagie Maarten1, Coosemans Thierry1ORCID
Affiliation:
1. Electric Vehicle and Energy Research Group (EVERGI), Mobility, Logistics and Automotive Technology Research Centre (MOBI), Department of Electrical Engineering and Energy Technology, Vrije Universiteit Brussel, 1050 Brussels, Belgium 2. Faculty of Electrical and Computer Engineering, Jimma Institute of Technology, Jimma University, Jimma P.O. Box 378, Ethiopia
Abstract
Wind energy is an increasingly important renewable resource in today’s global energy landscape. However, it faces challenges due to the unpredictable nature of wind speeds, resulting in intermittent power generation. This intermittency can disrupt power grid stability when integrating doubly fed induction generators (DFIGs). To address this challenge, we propose integrating a Li-ion battery energy storage system (BESS) with the direct current (DC) link of grid-connected DFIGs to mitigate power fluctuations caused by variable wind speed conditions. Our approach entails meticulous battery modeling, sizing, and control methods, all tailored to match the required output power of DFIG wind turbines. To demonstrate how well our Li-ion battery solution works, we have developed a MATLAB/Simulink R2022a version model. This model enables us to compare situations with and without the Li-ion battery in various operating conditions, including steady-state and dynamic transient scenarios. We also designed a buck–boost bidirectional DC-DC converter controlled by a proportional integral controller for battery charging and discharging. The battery actively monitors the DC-link voltage of the DFIG wind turbine and dynamically adjusts its stored energy in response to the voltage level. Thus, DFIG wind turbines consistently generate 1.5 MW of active power, operating with a highly efficient power factor of 1.0, indicating there is no reactive power produced. Our simulation results confirm that Li-ion batteries effectively mitigate power fluctuations in grid-connected DFIG wind turbines. As a result, Li-ion batteries enhance grid power stability and quality by absorbing or releasing power to compensate for variations in wind energy production.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction
Reference88 articles.
1. IRENA (2022, December 20). Renewable Energy Capacity Highlights. Available online: https://www.irena.org/-/media/Files/IRENA/Agency/Publication/2021/Apr/IRENA_-RE_Capacity_Highlights_2021.pdf?la=en&hash=1E133689564BC40C2392E85026F71A0D7A9C0B91. 2. Real and reactive power control of hybrid excited wind-driven grid-connected doubly fed induction generators;Vijayakumar;IET Power Electron.,2013 3. Chhipą, A.A., Chakrabarti, P., Bolshev, V., Chakrabarti, T., Samarin, G., Vasilyev, A.N., Ghosh, S., and Kudryavtsev, A. (2022). Modeling and Control Strategy of Wind Energy Conversion System with Grid-Connected Doubly-Fed Induction Generator. Energies, 15. 4. Modeling and control of dynamic battery storage system used in hybrid grid;Sarita;Energy Storage,2020 5. Behabtu, H.A., Coosemans, T., Berecibar, M., Fante, K.A., Kebede, A.A., Van Mierlo, J., and Messagie, M. (2021). Performance Evaluation of Grid-Connected Wind Turbine Generators. Energies, 14.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|