Radiometric Cross-Calibration of Wide-Field-of-View Cameras Based on Gaofen-1/6 Satellite Synergistic Observations Using Landsat-8 Operational Land Imager Images: A Solution for Off-Nadir Wide-Field-of-View Associated Problems

Author:

Dong Jiadan1,Chen Yepei2,Chen Xiaoling1,Xu Qiangqiang3

Affiliation:

1. State Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Wuhan 430079, China

2. School of Computer Science, Hubei University of Technology, Wuhan 430068, China

3. The Northwest Institute of Eco-Environment and Resources (NIEER), Chinese Academy of Sciences (CAS), Lanzhou 730000, China

Abstract

The Gaofen-1 satellite is equipped with four wide-field-of-view (WFV) instruments, enabling an impressive spatial resolution of 16 m and a combined swath exceeding 800 km. These WFV images have shown their valuable applications across diverse fields. However, achieving accurate radiometric calibration is an essential prerequisite for establishing reliable connections between satellite signals and biophysical, as well as biochemical, parameters. However, observations with large viewing angles (>20°) pose new challenges due to the bidirectional reflectance distribution function (BRDF) effect having a pronounced impact on the accuracy of cross-radiation calibrations, especially for the off-nadir WFV1 and WFV4 cameras. To overcome this challenge, a novel approach was introduced utilizing the combined observations from the Gaofen-1 and Gaofen-6 satellites, with Landsat-8 OLI serving as a reference sensor. The key advantage of this synergistic observation strategy is the ability to obtain a greater number of image pairs that closely resemble Landsat-8 OLI reference images in terms of geometry and observation dates. This increased availability of matching images ensures a more representative dataset of the observation geometry, enabling the derived calibration coefficients to be applicable across various sun–target–sensor geometries. Then, the geometry angles and bidirectional reflectance information were put into a Particle Swarm Optimization (PSO) algorithm incorporating radiative transfer modeling. This PSO-based approach formulates cross-calibration as an optimization problem, eliminating the reliance on complex BRDF models and satellite-based BRDF products that can be affected by cloud contamination. Extensive validation experiments involving satellite data and in situ measurements demonstrated an average uncertainty of less than eight percent for the proposed cross-radiation calibration scheme. Comparisons of top-of-atmosphere (TOA) results calibrated using our proposed scheme, the previous traditional radiative transfer modeling using MODIS BRDF products for BRDF correction (RTM-BRDF) method, and official coefficients reveal the superior accuracy of our method. The proposed scheme achieves a 36.99% decrease in root mean square error (RMSE) and a 38.13% increase in mean absolute error (MAE) compared to official coefficients. Moreover, it achieves comparable accuracy to the RTM-BRDF method while eliminating the need for MODIS BRDF products, with a decrease in RMSE exceeding 14% for the off-nadir WFV1 and WFV4 cameras. The results substantiate the efficacy of the proposed scheme in enhancing cross-calibration accuracy by improving image match-up selection, efficiently removing BRDF effects, and expanding applicability to diverse observation geometries.

Funder

National Natural Science Foundation of China

Publisher

MDPI AG

Subject

General Earth and Planetary Sciences

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3