Flow Measurements Using a Sluice Gate; Analysis of Applicability

Author:

Kubrak ElżbietaORCID,Kubrak JanuszORCID,Kiczko AdamORCID,Kubrak MichałORCID

Abstract

This study analyzes the possibilities of using an irrigation sluice gate in submerged conditions to measure water flow rate. Hydraulic experiments on sluice gate discharge capacity were performed on a model made on a 1:2 scale. Measurements were taken for the submerged flow of the sluice gate. Nomograms and relationships for discharge coefficients of the analyzed sluice gate were developed. The possibility of using the existing nomogram for discharge capacity of the submerged sluice gate to determine the discharge capacity of the modeled gate was also investigated. The effect of narrowing of the sluice gate cross-section resulting from different mounting techniques on its capacity was explained. The analyses confirmed the possibility of using the formulas for the submerged sluice gate to estimate the flow through the irrigation sluice gate.

Publisher

MDPI AG

Subject

Water Science and Technology,Aquatic Science,Geography, Planning and Development,Biochemistry

Reference20 articles.

1. Calibration of Submerged Radial Gates

2. Calibration of Water-Drainage Structures;Kaca,1996

3. Assessment of the Error in Estimating an Output Coefficient Value for a Melioration Gate Weirs;Jędryka,1998

4. Field Calibration of Submerged Sluice Gates in Irrigation Canals

5. Calculation of Contraction Coefficient under Sluice Gates and Application to Discharge Measurement

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3