Determination of MLC model parameters for Monaco using commercial diode arrays
Author:
Affiliation:
1. Physics Department; Saint Luke's Hospital; Dublin Ireland
2. School of Physics, Science Centre - North, University College Dublin; Belfield Dublin Ireland
Funder
St. Luke's Cancer Research Fund
St. Luke's Radiation Oncology Network
Dr. Luis Léon Vintro at University College Dublin School of Physics
Publisher
Wiley
Subject
Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation
Link
http://onlinelibrary.wiley.com/wol1/doi/10.1120/jacmp.v17i4.6190/fullpdf
Reference29 articles.
1. Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM Radiation Therapy Committee;Ezzell;Med Phys.,2003
2. Quality assurance in IMRT: importance of the transmission through the jaws for an accurate calculation of absolute doses and relative distributions;Azcona;Med Phys.,2002
3. Evaluating IMRT and VMAT dose accuracy: practical examples of failure to detect systematic errors when applying a commonly used metric and action levels;Nelms;Med Phys.,2013
4. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation;Sikora;Phys Med Biol.,2007
Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Multileaf Collimator Modeling and Commissioning for Complex Radiation Treatment Plans Using 2-Dimensional (2D) Diode Array MapCHECK2;Technology in Cancer Research & Treatment;2024-01
2. Transmission probability filter optimization for Agility MLC in Monaco treatment planning system;Journal of Applied Clinical Medical Physics;2023-07-26
3. Effects of high-resolution measurements between different multi-row detectors on volumetric modulated arc therapy patient-specific quality assurance;INT J RADIAT RES;2023
4. Effects of high-resolution measurements between different multi-row detectors on volumetric modulated arc therapy patient-specific quality assurance;International Journal of Radiation Research;2023-06-01
5. Impact of systematic MLC positional uncertainties on the quality of single‐isocenter multi‐target VMAT‐SRS treatment plans;Journal of Applied Clinical Medical Physics;2022-06-22
1.学者识别学者识别
2.学术分析学术分析
3.人才评估人才评估
"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370
www.globalauthorid.com
TOP
Copyright © 2019-2024 北京同舟云网络信息技术有限公司 京公网安备11010802033243号 京ICP备18003416号-3