Determination of Polycyclic Aromatic Hydrocarbons in Commercial Parenteral Formulations and Medications Using High-Performance Liquid Chromatography with Diode Array Detection

Author:

Barichello Marcia M1,Bohrer Denise1,Viana Carine1,Carvalho Leandro M2,Nascimento Paulo C2

Affiliation:

1. Federal University of Santa Maria, Postgraduate Program in Pharmaceutical Sciences, Avenida Roraima 1000, Santa Maria 97105-900, Brazil

2. Federal University of Santa Maria, Department of Chemistry, Avenida Roraima 1000, Santa Maria, 97105-900, Brazil

Abstract

Abstract HPLC coupled to UV diode array detection (DAD) is proposed for the determination of polycyclic aromatic hydrocarbons (PAHs) in pharmaceutical products for parenteral administration. Because rubber is a possible source of PAHs for these products, samples stored in containers with rubber parts were selected for the analysis. The basis for method optimization was EPA Method 8310, which determines 16 priority PAHs in ground water and wastewater by HPLC using both UV and fluorescence detection. Using DAD, two channels were selected for detection, with one operating at 254 nm for the detection of nine PAHs and the other at 225 nm for the detection of seven PAHs. This method allowed for the detection of PAHs using external calibration with LODs and LOQs ranging from 0.001 to 0.060 µg/mL and from 0.003 to 0.167 µg/mL, respectively. Within-day precision, expressed as RSD, varied from 1.24 to 7.76% for PAH concentrations from 0.05 to 0.50 µg/mL, and intraday precision varied from 3.10 to 9.40% for the same concentration range. Method accuracy was confirmed by recoveries of 75–120% of the spiked samples. This method was applied for the determination of PAHs in three commercial infusion solutions and in nine different medications stored in syringes prior to administration to patients. Twelve of 16 PAHs were found in these samples. Total PAH concentrations varied from 0.13 to 13.50 µg/mL. Pyrene was the most prevalent contaminant, being present in 11 of 12 samples in concentrations ranging from 0.17 to 4.80 µg/mL. This method presented good sensitivity for the measurement of PAH in the target samples, allowing for the determination of the 16 priority PAHs in one run and in 30 min.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3