Image registration and mutual thresholding enable low interimage variability across dynamic MRI measurements of supraclavicular brown adipose tissue during mild cold exposure

Author:

Sardjoe Mishre Aashley S. D.123ORCID,Martinez‐Tellez Borja12ORCID,Straat Maaike E.12ORCID,Boon Mariëtte R.12ORCID,Dzyubachyk Oleh45ORCID,Webb Andrew G.3ORCID,Rensen Patrick C. N.12ORCID,Kan Hermien E.3ORCID

Affiliation:

1. Department of Medicine, Division of Endocrinology Leiden University Medical Center Leiden the Netherlands

2. Einthoven Laboratory for Experimental Vascular Medicine Leiden University Medical Center Leiden the Netherlands

3. Department of Radiology, C.J. Gorter MRI Center Leiden University Medical Center Leiden the Netherlands

4. Department of Radiology, Division of Image Processing Leiden University Medical Center Leiden the Netherlands

5. Department of Cell and Chemical Biology, Electron Microscopy Section Leiden University Medical Center Leiden the Netherlands

Abstract

PurposeActivated brown adipose tissue (BAT) enhances lipid catabolism and improves cardiometabolic health. Quantitative MRI of the fat fraction (FF) of supraclavicular BAT (scBAT) is a promising noninvasive measure to assess BAT activity but suffers from high scan variability. We aimed to test the effects of coregistration and mutual thresholding on the scan variability in a fast (1 min) time‐resolution MRI protocol for assessing scBAT FF changes during cold exposure.MethodsTen volunteers (age 24.8 ± 3.0 years; body mass index 21.2 ± 2.1 kg/m2) were scanned during thermoneutrality (32°C; 10 min) and mild cold exposure (18°C; 60 min) using a 12‐point gradient‐echo sequence (70 consecutive scans with breath‐holds, 1.03 min per dynamic).Dynamics were coregistered to the first thermoneutral scan, which enabled drawing of single regions of interest in the scBAT depot. Voxel‐wise FF changes were calculated at each time point and averaged across regions of interest. We applied mutual FF thresholding, in which voxels were included if their FF was greater than 30% FF in the reference scan and the registered dynamic. The efficacy of the coregistration was determined by using a moving average and comparing the mean squared error of residuals between registered and nonregistered data. Registered scBAT ΔFF was compared with single‐scan thresholding using the moving average method.ResultsRegistered scBAT ΔFF had lower mean square error values than nonregistered data (0.07 ± 0.05% vs. 0.16 ± 0.14%; p < 0.05), and mutual thresholding reduced the scBAT ΔFF variability by 30%.ConclusionWe demonstrate that coregistration and mutual thresholding improve stability of the data 2‐fold, enabling assessment of small changes in FF following cold exposure.

Funder

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3