Dixon‐based B0 self‐navigation in radial stack‐of‐stars multi‐echo gradient echo imaging

Author:

Stelter Jonathan1ORCID,Weiss Kilian2,Wu Mingming13ORCID,Raspe Johannes1,Braun Philipp1,Zöllner Christoph1,Karampinos Dimitrios C.145

Affiliation:

1. Institute of Diagnostic and Interventional Radiology, School of Medicine and Health Technical University of Munich Munich Germany

2. Philips GmbH Market DACH Hamburg Germany

3. Department of Radiology LMU University Hospital Munich Germany

4. Munich Institute of Biomedical Engineering Technical University of Munich Garching Germany

5. Munich Data Science Institute Technical University of Munich Garching Germany

Abstract

AbstractPurposeTo develop a Dixon‐based self‐navigation approach to estimate and correct temporal variations in radial stack‐of‐stars gradient echo imaging for quantitative body MRI.MethodsThe proposed method estimates temporal variations using a self‐navigator estimated by a graph‐cut‐based water‐fat separation algorithm on the oversampled k‐space center. The self‐navigator was employed to correct for phase differences between radial spokes (one‐dimensional [1D] correction) and to perform a motion‐resolved reconstruction to correct spatiotemporal pseudo‐periodic variations (three‐dimensional [3D] correction). Numerical simulations, phantom experiments and in vivo neck scans were performed to evaluate the effects of temporal variations on the field‐map, proton density fat fraction (PDFF) and map, and to validate the proposed method.ResultsTemporal variations were found to cause signal loss and phase shifts on the multi‐echo images that lead to an underestimation of , while PDFF mapping was less affected. The self‐navigator captured slowly varying temporal drifts and temporal variations caused by respiratory motion. While the 1D correction effectively corrected drifts in phantom studies, it was insufficient in vivo due to 3D spatially varying temporal variations with amplitudes of up to 25 Hz at 3 T near the lungs. The proposed 3D correction locally improved the correction of field‐map and and reduced image artifacts.ConclusionTemporal variations particularly affect mapping in radial stack‐of‐stars imaging. The self‐navigation approach can be applied without modifying the MR acquisition to correct for drift and physiological motion‐induced variations, especially in the presence of fat.

Funder

International Graduate School of Science and Engineering

Philips Medical Systems

Deutsche Forschungsgemeinschaft

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3