A robust evaluation of 49 high‐dose‐rate prostate brachytherapy treatment plans including all major uncertainties

Author:

Kennedy Andrew Christopher1ORCID,Douglass Michael John James123,Santos Alexandre Manuel Caraça123

Affiliation:

1. School of Physical Sciences University of Adelaide Adelaide SA Australia

2. Department of Radiation Oncology Royal Adelaide Hospital Adelaide SA Australia

3. Australian Bragg Centre for Proton Therapy and Research Adelaide SA Australia

Abstract

AbstractBackgroundUncertainties in radiotherapy cause deviation from the planned dose distribution and may result in delivering a treatment that fails to meet clinical objectives. The impact of uncertainties is unique to the patient anatomy and the needle locations in HDR prostate brachytherapy. Evaluating this impact during treatment planning is not common practice, relying on margins around the target or organs‐at‐risk to account for uncertainties.PurposeA robust evaluation framework for HDR prostate brachytherapy treatment plans was evaluated on 49 patient plans, measuring the range of possible dosimetric outcomes to the patient due to 14 major uncertainties.MethodsPatient plans were evaluated for their robustness to uncertainties by simulating probable uncertainty scenarios. Five‐thousand probabilistic and 1943 worst‐case scenarios per patient were simulated by changing the position and size of structures and length of dwell times from their nominal values. For each uncertainty scenario, the prostate D90 and maximum doses to the urethra, D0.01cc, and rectum, D0.1cc, were calculated.ResultsThe D90 was an average 1.16 ± 0.51% (mean ± SD) below nominal values for the probabilistic scenarios; the D0.01cc metric was 2.24 ± 0.90% higher; and D0.1cc was greater by 0.48 ± 0.30%. The D0.01cc and D90 metrics were more sensitive to uncertainties than D0.1cc, with a median of 79.0% and 84.9% of probabilistic scenarios passing the constraints, compared to 96.5%. The median pass‐rate for scenarios that passed all three metrics simultaneously was 63.4%.ConclusionsAssessing treatment plan robustness improves plan quality assurance, is achievable in less than 1‐min, and identifies treatment plans with poor robustness, allowing re‐optimization before delivery.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370