A robust optimisation genetic algorithm for HDR prostate brachytherapy including all major uncertainties I: Algorithm implementation

Author:

Kennedy Andrew C.1ORCID,Douglass Michael J. J.1ORCID,Santos Alexandre M. C.1ORCID

Affiliation:

1. School of Physical Sciences, University of Adelaide, Adelaide, South Australia 5005, Australia

Abstract

Abstract Introduction In high-dose-rate prostate brachytherapy, uncertainties cause a deviation from the nominal treatment plan, leading to a possible failure of clinical objectives in the delivered scenario. Robust optimisation has the potential to maximise the probability that these objectives are met during treatment. Method A computationally efficient probabilistic robust optimisation algorithm was developed and evaluated comprehensively on one patient by comparing it to the treatment-planning-systems (TPS) optimised plan. Three objective functions were maximised within a genetic algorithm (NSGA-ii), each an approximation for robustness against uncertainty for three clinical objectives: the minimum dose to the hottest 90% of the prostate target, , and the maximum doses to the urethra, ,and the rectum, . The approximations are derived from a probabilistic robust evaluation algorithm incorporating 14 major planning and treatment uncertainties. The robustness of a plan was quantified as a pass-rate from 500 probabilistic uncertainty scenarios for , and .Two hundred robust-optimised plans are generated that are the best trade-off between the three-competing DVH metric pass-rates. Results The robust-optimised plans on average (mean) increased in overall robustness by 58.5±3.0%(SD: 7.1%, min: 34.1%, max: 67.7%) compared to the TPS-optimised plan. The robustness increase for the pass-rate was 31.2±2.2%(SD: 15.6%, min: -5.1%, max: 46.7%), for the pass-rate, the increase was 48.2±2.6%(SD: 11.9%, min: 26.9%, max: 67.7%), and for the pass-rate, the change was 0.0±1.1%(SD: 0.72%, min: -2.6%, max: 0.4%). Conclusion The robust optimisation algorithm was demonstrated to produce more robust plans than the TPS, in an increased probability of target coverage and organs-at-risk sparing within a clinically reasonable time.

Publisher

Research Square Platform LLC

Reference24 articles.

1. International Commission on Radiation Units and Measurements (1999) ICRU Report 62: Prescribing, Recording, and Reporting Photon Beam Therapy (Supplement to ICRU Report 50)

2. Time of PTV is ending, robust optimization comes next;Biston MC;Cancer/Radiothérapie,2020

3. PTV margins should not be used to compensate for uncertainties in 3D image guided intracavitary brachytherapy;Tanderup K;Radiother Oncol,2010

4. Robust optimization of dose-volume metrics for prostate HDR-brachytherapy incorporating target and oar volume delineation uncertainties;Balvert M;INFORMS J Comput,2019

5. Robust optimization for HDR prostate brachytherapy applied to organ reconstruction uncertainty;Meer MC;Phys Med Biol,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献