Robust optimization for HDR prostate brachytherapy applied to organ reconstruction uncertainty

Author:

van der Meer Marjolein C,Bosman Peter A N,Niatsetski Yury,Alderliesten Tanja,Pieters Bradley R,Bel Arjan

Abstract

Abstract Purpose. Recently, we introduced a bi-objective optimization approach based on dose-volume indices to automatically create clinically good HDR prostate brachytherapy plans. To calculate dose-volume indices, a reconstruction algorithm is used to determine the 3D organ shape from 2D contours, inevitably containing settings that influence the result. We augment the optimization approach to quickly find plans that are robust to differences in 3D reconstruction. Methods. Studied reconstruction settings were: interpolation between delineated organ contours, overlap between contours, and organ shape at the top and bottom contour. Two options for each setting yields 8 possible 3D organ reconstructions per patient, over which the robust model defines minimax optimization. For the original model, settings were based on our treatment planning system. Both models were tested on data of 26 patients and compared by re-evaluating selected optimized plans both in the original model (1 organ reconstruction, the difference determines the cost), and in the robust model (8 organ reconstructions, the difference determines the benefit). Results. Robust optimization increased the run time from 3 to 6 min. The median cost for robust optimization as observed in the original model was −0.25% in the dose-volume indices with a range of [−0.01%, −1.03%]. The median benefit of robust optimization as observed in the robust model was 0.93% with a range of [0.19%, 4.16%]. For 4 patients, selected plans that appeared good when optimized in the original model, violated the clinical protocol with more than 1% when considering different settings. This was not the case for robustly optimized plans. Conclusions. Plans of high quality, irrespective of 3D organ reconstruction settings, can be obtained using our robust optimization approach. With its limited effect on total runtime, our approach therefore offers a way to account for dosimetry uncertainties that result from choices in organ reconstruction settings that is viable in clinical practice.

Funder

Elekta

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3