Simultaneous dose and dose rate optimization via dose modifying factor modeling for FLASH effective dose

Author:

Ma Jiangjun1,Lin Yuting2,Tang Min1,Zhu Ya‐Nan2,Gan Gregory N.2,Rotondo Ronny L.2,Chen Ronald C.2,Gao Hao2

Affiliation:

1. Institute of Natural Sciences and School of Mathematics Shanghai Jiao Tong University Shanghai China

2. Department of Radiation Oncology University of Kansas Medical Center Kansas city Kansas USA

Abstract

AbstractBackgroundAlthough the FLASH radiotherapy (FLASH) can improve the sparing of organs‐at‐risk (OAR) via the FLASH effect, it is generally a tradeoff between the physical dose coverage and the biological FLASH coverage, for which the concept of FLASH effective dose (FED) is needed to quantify the net improvement of FLASH, compared to the conventional radiotherapy (CONV).PurposeThis work will develop the first‐of‐its‐kind treatment planning method called simultaneous dose and dose rate optimization via dose modifying factor modeling (SDDRO‐DMF) for proton FLASH that directly optimizes FED.MethodsSDDRO‐DMF models and optimizes FED using FLASH dose modifying factor (DMF) models, which can be classified into two categories: (1) the phenomenological model of the FLASH effect, such as the FLASH effectiveness model (FEM); (2) the mechanistic model of the FLASH radiobiology, such as the radiolytic oxygen depletion (ROD) model. The general framework of SDDRO‐DMF will be developed, with specific DMF models using FEM and ROD, as a demonstration of general applicability of SDDRO‐DMF for proton FLASH via transmission beams (TB) or Bragg peaks (BP) with single‐field or multi‐field irradiation. The FLASH dose rate is modeled as pencil beam scanning dose rate. The solution algorithm for solving the inverse optimization problem of SDDRO‐DMF is based on iterative convex relaxation method.ResultsSDDRO‐DMF is validated in comparison with IMPT and a state‐of‐the‐art method called SDDRO, with demonstrated efficacy and improvement for reducing the high dose and the high‐dose volume for OAR in terms of FED. For example, in a SBRT lung case of the dose‐limiting factor that the max dose of brachial plexus should be no more than 26 Gy, only SDDRO‐DMF met this max dose constraint; moreover, SDDRO‐DMF completely eliminated the high‐dose (V70%) volume to zero for CTV10mm (a high‐dose region as a 10 mm ring expansion of CTV).ConclusionWe have proposed a new proton FLASH optimization method called SDDRO‐DMF that directly optimizes FED using phenomenological or mechanistic models of DMF, and have demonstrated the efficacy of SDDO‐DMF in reducing the high‐dose volume or/and the high‐dose value for OAR, compared to IMPT and a state‐of‐the‐art method SDDRO.

Funder

National Institutes of Health

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3