Feasibility evaluation of novel AI‐based deep‐learning contouring algorithm for radiotherapy

Author:

Maduro Bustos Luis A.12,Sarkar Abhirup1,Doyle Laura A.12,Andreou Kelly1,Noonan Jodie1,Nurbagandova Diana1,Shah SunJay A.1,Irabor Omoruyi Credit2,Mourtada Firas2ORCID

Affiliation:

1. Department of Radiation Oncology Christiana Care Helen F. Graham Cancer Center Newark Delaware USA

2. Department of Radiation Oncology Thomas Jefferson University Hospital Philadelphia Pennsylvania USA

Abstract

AbstractPurposeTo evaluate the clinical feasibility of the Siemens Healthineers AI‐Rad Companion Organs RT VA30A (Organs‐RT) auto‐contouring algorithm for organs at risk (OARs) of the pelvis, thorax, and head and neck (H&N).MethodsComputed tomography (CT) datasets from 30 patients (10 pelvis, 10 thorax, and 10 H&N) were collected. Four sets of OARs were generated on each scan, one set by Organs‐RT and the others by three experienced users independently. A physician (expert) then evaluated each contour by assigning a score from the following scale: 1‐Must Redo, 2‐Major Edits, 3‐Minor Edits, 4‐Clinically usable. Using the highest‐scored OAR from the human users as a reference, the contours generated by Organs‐RT were evaluated via Dice Similarity Coefficient (DSC), Hausdorff Distance (HDD), Mean Distance to Agreement (mDTA), Volume comparison, and visual inspection. Additionally, each human user recorded the time to delineate each structure set and time‐saving efficiency was measured.ResultsThe average DSC obtained for the pelvic OARs ranged between (0.81 ± 0.06)Rectum and (0.94 ± 0.03)Bladder. (0.75 ± 0.09)Esophagus to for the thoracic OARs and (0.66 ± 0.07)Lips to (0.83 ± 0.04)Brainstem for the H&N. The average HDD in cm for the pelvis cohort ranged between (0.95 ± 0.35)Bladder to (3.62 ± 2.50)Rectum, (0.42 ± 0.06)SpinalCord to (2.09 ± 2.00)Esophagus for the thoracic set and to (1.50 ± 0.50)Mandible for the H&N region. The time‐saving efficiency was 67% for H&N, 83% for pelvis, and 84% for thorax. 72.5%, 82%, and 50% of the pelvis, thorax, and H&N OARs were scored as clinically usable by the expert, respectively.ConclusionsThe highest agreement registered between OARs generated by Organs‐RT and their respective references was for the bladder, heart, lungs, and femoral heads, with an overall DSC≥0.92. The poorest agreement was for the rectum, esophagus, and lips, with an overall DSC⩽0.81. Nonetheless, Organs‐RT serves as a reliable auto‐contouring tool by minimizing overall contouring time and increasing time‐saving efficiency in radiotherapy treatment planning.

Funder

Siemens Healthineers

National Cancer Institute

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3