A nonconvex model‐based combined geometric calibration scheme for micro cone‐beam CT with irregular trajectories

Author:

Li Guang1,Chen Xue1,You Chenyu2,Huang Xinhai1,Deng Zhenhao1,Luo Shouhua1

Affiliation:

1. Jiangsu Key Laboratory for Biomaterials and Devices Department of Biomedical Engineering Southeast University Nanjing China

2. Image Processing and Analysis Group (IPAG) Yale University New Haven Connecticut USA

Abstract

AbstractBackgroundMany dedicated cone‐beam CT (CBCT) systems have irregular scanning trajectories. Compared with the standard CBCT calibration, accurate calibration for CBCT systems with irregular trajectories is a more complex task, since the geometric parameters for each scanning view are variable. Most of the existing calibration methods assume that the intrinsic geometric relationship of the fiducials in the phantom is precisely known, and rarely delve deeper into the issue of whether the phantom accuracy is adapted to the calibration model.PurposeA high‐precision phantom and a highly robust calibration model are interdependent and mutually supportive, and they are both important for calibration accuracy, especially for the high‐resolution CBCT. Therefore, we propose a calibration scheme that considers both accurate phantom measurement and robust geometric calibration.MethodsOur proposed scheme consists of two parts: (1) introducing a measurement model to acquire the accurate intrinsic geometric relationship of the fiducials in the phantom; (2) developing a highly noise‐robust nonconvex model‐based calibration method. The measurement model in the first part is achieved by extending our previous high‐precision geometric calibration model suitable for CBCT with circular trajectories. In the second part, a novel iterative method with optimization constraints based on a back‐projection model is developed to solve the geometric parameters of each view.ResultsThe simulations and real experiments show that the measurement errors of the fiducial ball bearings (BBs) are within the subpixel level. With the help of the geometric relationship of the BBs obtained by our measurement method, the classic calibration method can achieve good calibration based on far fewer BBs. All metrics obtained in simulated experiments as well as in real experiments on Micro CT systems with resolutions of 9 and 4.5 μm show that the proposed calibration method has higher calibration accuracy than the competing classic method. It is particularly worth noting that although our measurement model proves to be very accurate, the classic calibration method based on this measurement model can only achieve good calibration results when the resolution of the measurement system is close to that of the system to be calibrated, but our calibration scheme enables high‐accuracy calibration even when the resolution of the system to be calibrated is twice that of the measurement system.ConclusionsThe proposed combined geometrical calibration scheme does not rely on a phantom with an intricate pattern of fiducials, so it is applicable in Micro CT with high resolution. The two parts of the scheme, the “measurement model” and the “calibration model,” prove to be of high accuracy. The combination of these two models can effectively improve the calibration accuracy, especially in some extreme cases.

Funder

National Natural Science Foundation of China

Jiangsu Provincial Key Research and Development Program

Publisher

Wiley

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3