Affiliation:
1. Department of Medicine 3 Friedrich‐Alexander‐University Erlangen‐Nürnberg and Universitätsklinikum Erlangen Erlangen Germany
2. Institute of Medical Physics Friedrich‐Alexander‐University Erlangen‐Nürnberg Erlangen Germany
3. Institute of Radiology Friedrich‐Alexander‐University Erlangen‐Nürnberg and Universitätsklinikum Erlangen Erlangen Germany
4. Division of Endocrinology and Kogod Center on Aging Mayo Clinic Rochester MN USA
Abstract
ABSTRACTOpportunistic screening is a new promising technique to identify individuals at high risk for osteoporotic fracture using computed tomography (CT) scans originally acquired for an clinical purpose unrelated to osteoporosis. In these CT scans, a calibration phantom traditionally required to convert measured CT values to bone mineral density (BMD) is missing. As an alternative, phantomless calibration has been developed. This study aimed to review the principles of four existing phantomless calibration methods and to compare their performance against the gold standard of simultaneous calibration (ΔBMD). All methods were applied to a dataset of 350 females scanned with a highly standardized CT protocol (DS1) and to a second dataset of 114 patients (38 female) from clinical routine covering a large range of CT acquisition and reconstruction parameters (DS2). Three of the phantomless calibration methods must be precalibrated with a reference dataset containing a calibration phantom. Sixty scans from DS1 and 57 from DS2 were randomly selected for this precalibration. For each phantomless calibration method first the best combination of internal reference materials (IMs) was selected. These were either air and blood or subcutaneous adipose tissue, blood, and cortical bone. In addition, for phantomless calibration a fifth method based on average calibration parameters derived from the reference dataset was applied. For DS1, ΔBMD results (mean standard deviation) for the phantomless calibration methods requiring a precalibration ranged from 0.1 2.7 mg/cm3 to 2.4 3.5 mg/cm3 with similar means but significantly higher standard deviations for DS2. Performance of the phantomless calibration method, which does not require a precalibration was worse (ΔBMD DS1: 12.6 13.2 mg/cm3, DS2: 0.5 8.8 mg/cm3). In conclusion, phantomless BMD calibration performs well if precalibrated with a reference dataset. © 2023 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).
Funder
Bundesministerium für Bildung und Forschung
Publisher
Oxford University Press (OUP)
Subject
Orthopedics and Sports Medicine,Endocrinology, Diabetes and Metabolism
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献