Technical note: Micro‐computed tomography calibration using dental tissue for bone mineral research

Author:

Towle Ian12ORCID,Loch Carolina2,Oxenham Marc34ORCID,Krueger Kristin L.5ORCID,Samir Salem Amira2,de Pinillos Marina Martínez16,Modesto‐Mata Mario17,Hlusko Leslea J.1

Affiliation:

1. Centro Nacional de Investigación sobre la Evolución Humana (CENIEH) Burgos Spain

2. Sir John Walsh Research Institute, Faculty of Dentistry University of Otago Dunedin New Zealand

3. School of Archaeology and Anthropology Australian National University Canberra Australia

4. Department of Archaeology, School of Geosciences University of Aberdeen Aberdeen UK

5. Department of Anthropology Loyola University Chicago Chicago IL USA

6. Laboratorio de Evolución Humana (LEH) Universidad de Burgos Burgos Spain

7. Universidad Internacional de La Rioja (UNIR) Logroño La Rioja Spain

Abstract

AbstractComputed tomography (CT) and microcomputed tomography (μCT) require calibration against density phantoms scanned with specimens or during routine internal calibration for assessment of mineral concentration (MC) and density. In clinical studies involving bone, alternative calibration methods using bodily tissues and fluids (“phantomless” calibration) have been suggested. However, such tissues are seldom available in archeological and osteological research. This study investigates the potential of dental tissue as internal reference for calibration of μCT scans, facilitating the analysis of bone MC. We analyzed 70 molars from 24 extant primate species, including eight human teeth, each scanned with density phantoms for calibration. Our findings indicate that sampling specific regions of molars (lateral aspects of the mesial cusps) yields low variation in enamel and dentine MC values, averaging 1.27 g/cm3 (±0.03) for dentine and 2.25 g/cm3 (±0.03) for enamel. No significant differences were observed across molar types or among scanning procedures, including scanner model, resolution, and filters. An ad hoc test on 12 mandibles revealed low variance in MC between the conventional phantom and dental tissue calibration methods; all 36 measurements (low, medium, and high MC for each mandible) were within 0.05 g/cm3 of each other —81% were within 0.03 g/cm3 and 94% within 0.04 g/cm3. Based on these results, we propose a new “phantomless” calibration technique using these mean enamel and dentine MC values. The presented phantomless calibration method could aid in the assessment of bone pathology and enhance the scope of studies investigating bone structure and physical property variations in archeological, osteological, and laboratory‐based research.

Funder

Sir John Walsh Research Institute, University of Otago

HORIZON EUROPE European Innovation Ecosystems

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3