Affiliation:
1. School of Microelectronics Dalian University of Technology Dalian Liaoning 116024 P. R. China
Abstract
AbstractNon‐invasive breath testing has gained increasing importance for early disease screening, spurring research into cheap sensors for detecting trace biomarkers such as ammonia. However, real‐life deployment of ammonia sensors remains hindered by susceptibility to humidity‐induced interference. The SnTe/SnSe heterojunction‐based chemiresistive‐type sensor demonstrates an excellent response/recovery to different concentrations of ammonia from 0.1 to 100 ppm at room temperature. The improved sensing properties of the heterojunctions‐based sensors compared to single‐phased SnTe or SnSe can be attributed to the stronger NH3 adsorptions, more Te vacancies, and hydrophobic surface induced by the formed SnTe/SnSe heterojunctions. The sensing mechanisms are investigated in detail by using in situ techniques such as diffuse reflectance Fourier transform infrared spectroscopy (DRIFTS), Kelvin probe, and a.c. impedance spectroscopy together with the Density‐Function‐Theory calculations. The formed heterojunctions boost the overall charge transfer efficiency between the ammonia and the sensing materials, thus leading to the desirable sensing features as well, with excellent resistance to ambient humidities.
Funder
National Basic Research Program of China
National Natural Science Foundation of China
Fundamental Research Funds for the Central Universities
Subject
Biomaterials,Biotechnology,General Materials Science,General Chemistry
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献