Abstract

The fluorinated titanium dioxide (F-TiO2) hollow spheres with varying F to Ti molar ratios were prepared by a simple one-step hydrothermal method followed by thermal processing. The diameter of the F-TiO2-0.3 hollow spheres with a nominal ratio of F:Ti = 0.3:1 was about 200–400 nm. Compared with the sensor based on pristine TiO2 sensing materials, the F-TiO2-0.3 sensor displayed an enhanced sensing performance toward gaseous formaldehyde (HCHO) vapor at room temperature under ultraviolet (UV) light irradiation. The F-TiO2-0.3 sensor demonstrated an approximately 18-fold enhanced response (1.56) compared to the pristine TiO2 sensor (0.085). The response and recovery times of the F-TiO2-0.3 sensor to 10 ppm HCHO were about 56 s and 64 s, respectively, and a limit-of-detection value of 0.5 ppm HCHO was estimated. The F-TiO2-0.3 sensor also demonstrated good repeatability and selectivity to HCHO gas under UV light irradiation. The outstanding HCHO gas-sensing properties of the F-TiO2-0.3 sensor were related to the following factors: the excitation effect caused by the UV light facilitated surface chemical reactions with analyte gas species; the hollow sphere structure provided sufficient active sites; and the surface fluoride (≡Ti−F) created additional chemisorption sites on the surface of the TiO2 material.

Funder

National Key R&D Program of China

National Natural Science Foundation of China

Fundamental Research Funds for the Central Universities

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3