Feasibility study of multiple‐energy Bragg peak proton FLASH on a superconducting gantry with large momentum acceptance

Author:

Zeng Yiling123,Li Heng4,Wang Wei5,Liu Xu5,Qin Bin5,Dai Shuyang6,Pang Bo1,Liu Muyu1,Quan Hong1,Yang Kunyu23,Chang Yu23,Yang Zhiyong23

Affiliation:

1. Department of Medical Physics, School of Physics and Technology Wuhan University Wuhan China

2. Cancer Center, Union Hospital, Tongji Medical College Huazhong University of Science and Technology Wuhan China

3. Hubei Key Laboratory of Precision Radiation Oncology Wuhan China

4. Department of Radiation Oncology and Molecular Radiation Sciences Johns Hopkins University Baltimore Maryland USA

5. State Key Laboratory of Advanced Electromagnetic Engineering and Technology School of Electrical and Electronic Engineering Huazhong University of Science and Technology Wuhan China

6. School of Mathematics and Statistics Wuhan University Wuhan P. R. China

Abstract

AbstractBackgroundWhile the Bragg peak proton beam (BP) is capable of superior target conformity and organs‐at‐risk sparing than the transmission proton beam (TB), its efficacy in FLASH‐RT is hindered by both a slow energy switching process and the beam current. A universal range shifter (URS) can pull back the high‐energy proton beam while preserving the beam current. Meanwhile, a superconducting gantry with large momentum acceptance (LMA‐SC gantry) enables fast energy switching.PurposeThis study explores the feasibility of multiple‐energy BP FLASH‐RT on the LMA‐SC gantry.Method and MaterialsA simultaneous dose and spot map optimization algorithm was developed for BP FLASH‐RT treatment planning to improve the dose delivery efficiency. The URS was designed to be 0–27 cm thick, with 1 cm per step. BP plans using the URS were optimized using single‐field optimization (SFO) and multiple‐field optimization (MFO) for ten prostate cancer patients and ten lung cancer patients. The plan delivery parameters, dose, and dose rate metrics of BP plans were compared to those of TB plans using the parameters of the LMA‐SC gantry.ResultsCompared to TB plans, BP plans significantly reduced MUs by 42.7% (P < 0.001) with SFO and 33.3% (P < 0.001) with MFO for prostate cases. For lung cases, the reduction in MUs was 56.8% (P < 0.001) with SFO and 36.4% (P < 0.001) with MFO. BP plans also outperformed TB plans by reducing mean normal tissue doses. BP‐SFO plans achieved a reduction of 56.7% (P < 0.001) for prostate cases and 57.7% (P < 0.001) for lung cases, while BP‐MFO plans achieved a reduction of 54.2% (P < 0.001) for the prostate case and 40.0% (P < 0.001) for lung cases. For both TB and BP plans, normal tissues in prostate and lung cases received 100.0% FLASH dose rate coverage (>40 Gy/s).ConclusionsBy utilizing the URS and the LMA‐SC gantry, it is possible to perform multiple‐energy BP FLASH‐RT, resulting in better normal tissue sparing, as compared to TB plans.

Funder

National Key Research and Development Program of China

Fundamental Research Funds for the Central Universities

State Key Laboratory of Advanced Electromagnetic Engineering and Technology

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3