Technical note: Dosimetry and FLASH potential of UHDR proton PBS for small lung tumors: Bragg‐peak‐based delivery versus transmission beam and IMPT

Author:

van Marlen Patricia1,van de Water Steven1,Slotman Ben J.1,Dahele Max1,Verbakel Wilko2

Affiliation:

1. Department of Radiation Oncology Amsterdam UMC Cancer Center Amsterdam Amsterdam the Netherlands

2. Varian Medical Systems, Inc Palo Alto California USA

Abstract

AbstractBackgroundHigh‐energy transmission beams (TBs) are currently the main delivery method for proton pencil beam scanning ultrahigh dose‐rate (UHDR) FLASH radiotherapy. TBs place the Bragg‐peaks behind the target, outside the patient, making delivery practical and achievement of high dose‐rates more likely. However, they lead to higher integral dose compared to conventional intensity‐modulated proton therapy (IMPT), in which Bragg‐peaks are placed within the tumor. It is hypothesized that, when energy changes are not required and high beam currents are possible, Bragg‐peak‐based beams can not only achieve more conformal dose distributions than TBs, but also have more FLASH‐potential.PurposeThis works aims to verify this hypothesis by taking three different Bragg‐peak‐based delivery techniques and comparing them with TB and IMPT‐plans in terms of dosimetry and FLASH‐potential for single‐fraction lung stereotactic body radiotherapy (SBRT).MethodsFor a peripherally located lung target of various sizes, five different proton plans were made using “matRad” and inhouse‐developed algorithms for spot/energy‐layer/beam reduction and minimum monitor unit maximization: (1) IMPT‐plan, reference for dosimetry, (2) TB‐plan, reference for FLASH‐amount, (3) pristine Bragg‐peak plan (non‐depth‐modulated Bragg‐peaks), (4) Bragg‐peak plan using generic ridge filter, and (5) Bragg‐peak plan using 3D range‐modulated ridge filter.ResultsBragg‐peak‐based plans are able to achieve sufficient plan quality and high dose‐rates. IMPT‐plans resulted in lowest OAR‐dose and integral dose (also after a FLASH sparing‐effect of 30%) compared to both TB‐plans and Bragg‐peak‐based plans. Bragg‐peak‐based plans vary only slightly between themselves and generally achieve lower integral dose than TB‐plans. However, TB‐plans nearly always resulted in lower mean lung dose than Bragg‐peak‐based plans and due to a higher amount of FLASH‐dose for TB‐plans, this difference increased after including a FLASH sparing‐effect.ConclusionThis work indicates that there is no benefit in using Bragg‐peak‐based beams instead of TBs for peripherally located, UHDR stereotactic lung radiotherapy, if lung dose is the priority.

Funder

Varian Medical Systems

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3