Validation of the IOTA ADNEX Model Among Japanese Women Performed by Gynecology Trainees and Ultrasound Specialists

Author:

Kadooka Mizuho1ORCID,Suemitsu Tokumasa1ORCID,Ashimoto Kensuke1,Takesawa Ami1,Matsui Hiroki2,Otsuka Isao1,Tajima Atsushi3

Affiliation:

1. Obstetrics/Gynecology Kameda Medical Center Chiba Japan

2. Clinical Research Support Division, Kameda Institute for Health Science Kameda College of Health Sciences Chiba Japan

3. Obstetrics/Gynecology Kyorin University Faculty of Medicine Tokyo Japan

Abstract

ObjectivesThis study aimed to validate the diagnostic accuracy of the International Ovarian Tumor Analysis (IOTA) Assessment of Different NEoplasias in the adneXa (ADNEX) model in Japanese women, population with a distinct adnexal mass distribution compared with European women, and to evaluate the model's utility by gynecology trainees and ultrasound specialists.MethodsThis single‐center, retrospective study analyzed ultrasound data from January 2017 to March 2020 of 206 women with adnexal masses. Patients who underwent ultrasonography and serum CA‐125 measurement and received postsurgery histological diagnosis were included. The ADNEX model's diagnostic performance was evaluated by two trainees and two specialists using the area under the receiver operating characteristic curve (AUC) and measures of accuracy, sensitivity, specificity, and predictive values for overall performance and each examiner.ResultsOf the 206 included Japanese women, the prevalence of malignancy was 30.1%, including borderline cases. The overall AUC for distinguishing malignancy was 0.848 (95% confidence interval [CI]: 0.817–0.880). The AUC for each examiner ranged from 0.791 to 0.898, with Specialist 2 showing the highest accuracy and sensitivity varying between 0.677 and 0.839. A moderate degree of agreement was noted among the four examiners (Fleiss' kappa was 0.586). The performance of trainees and specialists differed significantly in evaluating the solid tissue and the papillary projections in both malignant and benign groups (P < .001).ConclusionsThe IOTA ADNEX model effectively differentiates benign and malignant adnexal masses in Japanese women. Although the accuracy matched up moderately among the four examiners, better accuracy is expected with training in evaluating solid tissue and papillary projections.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3