Affiliation:
1. Radiation Oncology Department Institut Curie PSL Research University Orsay France
2. Thales Avionics Vélizy‐Villacoublay France
3. Institut Curie PSL Research University University Paris Saclay INSERM LITO Orsay France
Abstract
AbstractBackgroundVery high‐energy electrons (VHEE) radiotherapy, in the energy range of 100–200 MeV is currently considered a promising technique for the future of radiation therapy and could benefit from the promises of ultra‐high dose rate FLASH therapy. However, to our knowledge, no analytical calculation models have been tested for this type of application and the approximations proposed for multiple scattering with electron beams have not been extensively evaluated at these high energies.PurposeIn this work, we discuss the derivation of a simple and fast algorithm based on the Fermi‐Eyges theory of multiple Coulomb scattering for fast dose calculation for VHEE beams (up to 200 MeV). Similar to the Gaussian pencil beam models used for electron or proton beams, this pencil beam kernel is separated into a central and an off‐axis term. Monte Carlo simulations are performed to compare the analytical calculations with simulations and to determine the parametrizations used in the model at the highest electron energies.MethodsThe normalized electron planar fluence distribution is described in water according to the Fermi‐Eyges theory of multiple Coulomb scattering and a double Gaussian distribution model. The main quantities used in the model and their calculation (mass angular scattering power, mean energy, range straggling) are discussed and tested for electron energies up to 200 MeV. The TOPAS/Geant4 Monte Carlo (MC) toolkit is used to compare analytical calculations with MC simulations for a theoretical pencil beam irradiation and to find the best parameters describing the range straggling. The model is then tested on a realistic simulation of a pencil beam scanning beamline with treatment field dimensions up to 15 × 15 cm2 and for deep‐seated targets.ResultsRadial dose distributions of a pencil beam in water were calculated with the model and compared with the results of a complete Monte Carlo simulation. A good agreement (within 2%/2 mm gamma passing rate superior to 90%, and a mean deviation between calculated and simulated pencil beam radial spread smaller than 0.6 mm) was observed between analytical dose distributions and simulations for energies up to 200 MeV and field sizes up to 15 × 15 cm2.ConclusionsA parameterization of an electron source and an analytical pencil beam model were proposed in this work, thereby allowing a suitable reproduction of the lateral fluence of a VHEE beam and good agreement between calculations and simulated data. Further improvement of the method would require the consideration of a model describing the large‐angle scattering of the electrons. The results of this work could support future research into VHEE radiotherapy and might be of interest for use together with VHEE broad beams produced by scanned narrow pencil beams.
Funder
Grand Équipement National De Calcul Intensif
Varian Medical Systems
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献