Compensation cycle consistent generative adversarial networks (Comp‐GAN) for synthetic CT generation from MR scans with truncated anatomy

Author:

Zhao Yao12,Wang He12,Yu Cenji12,Court Laurence E.1,Wang Xin12,Wang Qianxia13,Pan Tinsu24,Ding Yao1,Phan Jack5,Yang Jinzhong12

Affiliation:

1. Department of Radiation Physics The University of Texas MD Anderson Cancer Center Houston Texas USA

2. The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences Houston Texas USA

3. Department of Radiation Oncology and Winship Cancer Institute Emory University Atlanta Georgia USA

4. Department of Imaging Physics The University of Texas MD Anderson Cancer Center Houston Texas USA

5. Department of Radiation Oncology The University of Texas MD Anderson Cancer Center Houston Texas USA

Abstract

AbstractBackgroundMR scans used in radiotherapy can be partially truncated due to the limited field of view (FOV), affecting dose calculation accuracy in MR‐based radiation treatment planning.PurposeWe proposed a novel Compensation‐cycleGAN (Comp‐cycleGAN) by modifying the cycle‐consistent generative adversarial network (cycleGAN), to simultaneously create synthetic CT (sCT) images and compensate the missing anatomy from the truncated MR images.MethodsComputed tomography (CT) and T1 MR images with complete anatomy of 79 head‐and‐neck patients were used for this study. The original MR images were manually cropped 10–25 mm off at the posterior head to simulate clinically truncated MR images. Fifteen patients were randomly chosen for testing and the rest of the patients were used for model training and validation. Both the truncated and original MR images were used in the Comp‐cycleGAN training stage, which enables the model to compensate for the missing anatomy by learning the relationship between the truncation and known structures. After the model was trained, sCT images with complete anatomy can be generated by feeding only the truncated MR images into the model. In addition, the external body contours acquired from the CT images with full anatomy could be an optional input for the proposed method to leverage the additional information of the actual body shape for each test patient. The mean absolute error (MAE) of Hounsfield units (HU), peak signal‐to‐noise ratio (PSNR), and structural similarity index (SSIM) were calculated between sCT and real CT images to quantify the overall sCT performance. To further evaluate the shape accuracy, we generated the external body contours for sCT and original MR images with full anatomy. The Dice similarity coefficient (DSC) and mean surface distance (MSD) were calculated between the body contours of sCT and original MR images for the truncation region to assess the anatomy compensation accuracy.ResultsThe average MAE, PSNR, and SSIM calculated over test patients were 93.1 HU/91.3 HU, 26.5 dB/27.4 dB, and 0.94/0.94 for the proposed Comp‐cycleGAN models trained without/with body‐contour information, respectively. These results were comparable with those obtained from the cycleGAN model which is trained and tested on full‐anatomy MR images, indicating the high quality of the sCT generated from truncated MR images by the proposed method. Within the truncated region, the mean DSC and MSD were 0.85/0.89 and 1.3/0.7 mm for the proposed Comp‐cycleGAN models trained without/with body contour information, demonstrating good performance in compensating the truncated anatomy.ConclusionsWe developed a novel Comp‐cycleGAN model that can effectively create sCT with complete anatomy compensation from truncated MR images, which could potentially benefit the MRI‐based treatment planning.

Funder

University of Texas MD Anderson Cancer Center

National Institutes of Health

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3