Gas‐phase ion mobility of protonated aldehydes in helium measured using a selected ion flow‐drift tube

Author:

Gnioua Maroua Omezzine12,Španěl Patrik1,Spesyvyi Anatolii1ORCID

Affiliation:

1. J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences Prague Czechia

2. Department of Surface and Plasma Science, Faculty of Mathematics and Physics Charles University Prague Prague Czechia

Abstract

RationaleIn soft chemical ionization mass spectrometry, analyte ions are produced via ion–molecule reactions in the reactor. When an electric field E is imposed, the ion drift velocity vd determines the reaction time and the effective ion temperature. Agreement between experimental ion mobilities and theoretical predictions confirms the accuracy of the ion residence time measurement procedure.MethodsA selected ion flow‐drift tube (SIFDT), an instrument with a chemical ionization source, was used to produce protonated aldehydes and selectively inject them into the resistive glass drift tube filled with He. Arrival‐time distributions of ions were obtained using the Hadamard modulation. Reduced ion mobilities were then obtained at a pressure of 2 hPa in the E/N range of 5–15 Td. Theoretical ion mobility values were calculated using two methods: hard‐sphere approximation and trajectory modelling.ResultsThe measured mobilities of three saturated and three unsaturated protonated aldehydes do not show substantial variation across the studied E/N range. Effective temperatures calculated using the Wannier formula from measured gas temperatures ranged from 300 to 315 K. Experimentally obtained values of the near‐zero‐ E/N‐reduced ion mobilities agree with both methods of calculations typically within ±3% standard deviation (maximum ±5%).ConclusionsThe experimental SIFDT values of reduced mobilities in He of protonated aldehyde molecules generated from a chemical ionization source are in close agreement with two different theoretical methods based on the density functional theory calculations of ion geometries and partial atomic charges. Besides its fundamental importance, the ion mobility results validate the correct operation of the drift tube reactor and the ion residence time measurement procedure. Diffusion losses can also be determined from these results.

Funder

Akademie Věd České Republiky

Grantová Agentura České Republiky

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3