Plan quality analysis of stereotactic ablative body radiotherapy treatment planning in liver tumor

Author:

Watcharawipha Anirut12ORCID,Chakrabandhu Somvilai12ORCID,Kongsa Anupong1ORCID,Tippanya Damrongsak1,Chitapanarux Imjai123ORCID

Affiliation:

1. Division of Radiation Oncology Department of Radiology Faculty of Medicine, Chiang Mai University Chiang Mai Thailand

2. Northern Thai Research Group of Radiation Oncology (NTRG‐RO) Faculty of Medicine, Chiang Mai University Chiang Mai Thailand

3. Chiang Mai Cancer Registry Maharaj Nakorn Chiang Mai Hospital Faculty of Medicine, Chiang Mai University Chiang Mai Thailand

Abstract

AbstractPurposeStereotactic ablative body radiotherapy (SABR) in the liver, RTOG‐1112 guides the treatment modalities including the dose constraints for this technique but not the plan parameters. This study is not only analyzing the plan quality by utilizing the plan parameters and indexes but also compares treatment modalities from the protocol implementation.Method and materialTwenty‐five patients treated in the period from February 2020 to September 2022 were recruited in this analysis. Two planners randomly selected the patients and modalities. The modalities employed were Volumetric‐Modulated Arc Therapy (VMAT) and Helical Tomotherapy (HT). Various parameters and indexes were used to access not only the plan quality but also to compare each modality. The parameters and indexes studied were the homogeneity index (HI), conformity index (CI), gradient distance (GD), and the dose received by the organs at risk.ResultThe data reveals that the mean volume of PTV is 60.8 ± 53.9 cc where these targets exhibit no significant difference between each modality. The HI shows a consistent value for both modalities. Between each modality, the CI value shows less deviation, but the HT shows slightly higher performance than VMAT. The value of GD is 1.5 ± 0.3 cm where the HT provides a shorter distance compared to VMAT as well.ConclusionThe parameters and indexes should be utilized for the plan evaluation although in the guidelines this was not required. Various modalities were employed for treatment. Both can achieve the treatment criteria with slightly low performance of VMAT.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3