Characterization of scanning orientation and lateral response artifact for EBT4 Gafchromic film

Author:

Miura Hideharu12,Ozawa Shuichi12,Okazue Toshiya1,Enosaki Tsubasa1,Nagata Yasushi12

Affiliation:

1. Hiroshima High‐Precision Radiotherapy Cancer Center Hiroshima Japan

2. Department of Radiation Oncology, Institute of Biomedical & Health Sciences Hiroshima University Hiroshima Japan

Abstract

AbstractThe purpose of this study was to investigate the impact of scanning orientation and lateral response artifact (LRA) effects on the dose‐response of EBT4 films and compare it with that of EBT3 films. Dose‐response curves for EBT3 and EBT4 films in red‐green‐blue (RGB) color channels in portrait orientation were created for unexposed films and for films exposed to doses ranging from 0 to 1 000 cGy. Portrait and landscape orientations of the EBT3 and EBT4 films were scanned to investigate the scanning orientation effect in the red channel. EBT3 and EBT4 films were irradiated to assess the LRA in the red channel using a field size of 15 × 15 cm2 and delivered doses of 200, 400, and 600 cGy. Films were scanned at the edge of the scanner bed, and the measured doses were compared with the treatment planning system (TPS) calculated doses at a position 100 mm lateral to the scanner center. At a dose of 200 cGy, the differences in optical density (OD) in the red, green, and blue color channels between EBT3 and EBT4 films were 0.035 (24.8%), 0.042 (49.7%), and 0.022 (64.4%), respectively. The EBT4 film slightly improved the scanning orientation compared to the EBT3 film. The OD difference in the different scanning orientations for the EBT3 and EBT4 films was 0.015 (6.8%) and 0.007 (3.9%), respectively, at a dose of 200 cGy. This is equivalent to a 20 or 10 cGy variation at a dose of 200 cGy. Compared with the TPS calculation, the measurement doses for EBT3 and EBT4 films irradiated at 200 cGy were approximately 16% and 13% higher, respectively, at the 100 mm off‐centered position. The EBT4 film showed an improvement concerning the impact of LRA compared with the EBT3 film. This study demonstrated that the response of EBT4 film to a dose in the blue channel was less sensitive and showed an improvement in the scanning orientation and LRA effects.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3