Characterization of Ethos therapy systems for adaptive radiation therapy: A multi‐machine comparison

Author:

van de Schoot Agustinus J.1,Hoffmans Daan2,van Ingen Karel M.1,Simons Martijn J.2,Wiersma Jan1

Affiliation:

1. Department of Radiation Oncology Amsterdam University Medical Center – location University of Amsterdam Amsterdam the Netherlands

2. Department of Radiation Oncology Amsterdam University Medical Center – location Vrije Universiteit Amsterdam Amsterdam the Netherlands

Abstract

AbstractPurposeThe recently released Ethos therapy system (Varian Medical Systems) allows for online CBCT‐guided adaptive radiation therapy (RT). The clinical introduction of multiple systems requires machine characterization and machine variation quantification to allow patient interchangeability between systems. Despite several clinical introductions, limited vendor‐independent information on machine performance is available. Our aim was to determine the relevant dosimetric and mechanical characteristics of individual machines and to quantify machine variations.MethodsSix Ethos treatment machines, equipped with a 6‐MV FFF beam including dual‐layer MLC and kV‐CBCT system, were recently introduced clinically after extensive machine characterization and pre‐configured beam model verification. Point doses and profiles were measured and compared to vendor‐provided reference data and dose calculations. Also, dose calculations were verified based on point measurements for non‐standard fields and dose distributions for optimized treatment plans. Agreements between dose profiles (dose distributions) were quantified using 1D (3D) γ‐analysis. Additionally, we quantified leaf transmission, dosimetric leaf gap (DLG) and couch attenuation, determined isocenter accuracy and kV‐MV isocenter coincidence and verified the kV‐CBCT system. Machine variations were quantified for all dosimetric and mechanical characteristics.ResultsFor all machines, distinct agreements were found between measurements and vendor‐provided reference data as well as measurements and dose calculations. Mean γ1%/1mm values for all profiles were below 0.30. All profiles, point measurements and dose distributions matched well among the six machines. Minimal machine variations were found in terms of DLG (0.05 mm), leaf transmission (0.001%), isocenter accuracy (0.08 mm), kV‐MV isocenter coincidence (0.15 mm), couch attenuation (0.69%), and CBCT imaging dose (0.29 mGy).ConclusionsThis study demonstrates excellent agreement between individual Ethos therapy systems and vendor‐provided reference data as well as a pre‐configured beam model. Furthermore, our results show good consistency among all machines and provide valuable insights on relevant machine characteristics. The systematically obtained results provide benchmark data for future clinical introduction of Ethos therapy systems.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3