The delivery assessment for small targets on Halcyon radiotherapy system – Measured and calculated dose comparison

Author:

Lankinen Linda12ORCID,Kulmala Antti3,Lehtomäki Jouko1,Harju Ari1

Affiliation:

1. Varian Medical Systems, a Siemens Healthineers Company Helsinki Finland

2. Department of Physics University of Helsinki Helsinki Finland

3. Clinical Research Institute HUCH Ltd. Helsinki Finland

Abstract

AbstractBackgroundWith the ever‐increasing requirements of accuracy and personalization of radiotherapy treatments, stereotactic radiotherapy (SRT) with volumetric modulated arc therapy (VMAT) on O‐ring Halcyon radiotherapy system could potentially provide a fast, safe, and feasible treatment option.PurposeThe purpose of this study was to assess the delivery of Halcyon VMAT plans for small targets.MethodsWell‐defined VMAT‐SRT plans were created on Halcyon radiotherapy system with the stacked and staggered dual‐layer MLC design for the film measurement set‐up and the target sizes and shapes designed to emulate the targets of the stereotactic treatments. The planar dose distributions were acquired with film measurements and compared to a current clinical reference dose calculation with AcurosXB (v18.0, Varian Medical Systems) and to Monte Carlo simulations. With the collapsed arc versions of the VMAT‐SRT plans, the uncertainty in dose delivery due to the multileaf collimator (MLC) without the gantry rotation could be separated and analyzed.ResultsThe target size was mainly limited by the resolution originated from the design of the MLC leaves. The results of the collapsed arc versions of the plans show good consistency among measured, calculated, and simulated dose distributions. With the full VMAT plans, the agreement between calculated and simulated dose distributions was consistent with the collapsed arc versions. The measured dose distribution agreed with the calculated and simulated dose distributions within the target regions, but considerable local differences were observed in the margins of the target. The largest differences located in the steep gradient regions presumably originating from the deviation of the isocenter.ConclusionsThe potential of the Halcyon radiotherapy system for VMAT‐SRT delivery was evaluated and the study revealed valuable insights on the machine characteristics with the delivery.

Funder

Varian Medical Systems

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3