Incomplete lipid extraction as a possible cause for underestimation of lipid oxidation in emulsions

Author:

Münch Katharina1ORCID,ten Klooster Sten1,van Kouwen Isabelle1,Berton‐Carabin Claire12,Schroën Karin1

Affiliation:

1. Wageningen University & Research, Laboratory of Food Process Engineering Wageningen The Netherlands

2. INRAE UR BIA Nantes France

Abstract

AbstractLipid oxidation deteriorates the sensory and nutritional quality of food emulsions containing polyunsaturated fatty acids. Classically, different extraction solvents are used as a first step to measure lipid oxidation in emulsions. However, it is unclear how the applied extraction method influences the measured lipid oxidation values. In this work, we systematically examined the performance of common solvent mixtures such as chloroform, methanol, and hexane (or isooctane)–isopropanol on lipid extraction from emulsions stabilized with different emulsifiers (Tween 20 (T20), whey proteins, and pea proteins) and oxidation levels, and how this, in turn, affected the measured hydroperoxide concentrations. Chloroform–methanol was the most effective solvent (lipid yield >93 wt.%). When using hexane–isopropanol, extraction yields were consistently high for T20‐ and pea protein‐based emulsions (>60 wt.%), but in whey protein‐based emulsions, values as low as 26 wt.% were measured. In case of incomplete extraction, hydroperoxide concentrations measured by colorimetric methods need to be corrected for this effect. When using 1H NMR to assess lipid oxidation, the actual amount of extracted lipids is intrinsically taken into account. This highlights not only the importance of the extraction method in determining lipid oxidation in emulsions but also that of the actual analysis method.Practical application: This study highlights that the lipid extraction yield can vary depending not only on the emulsion composition (e.g., type of emulsifier) but also on the oxidative state of the emulsion and the extraction solvent used. If this is overlooked, errors can be made in the hydroperoxide determination. Although these effects can be corrected for, this is not standard procedure, which implies that awareness on this matter should be increased. It is also important to point out that depending on the solvent used, the different lipid classes (including various lipid oxidation products) may be extracted at different levels. Chloroform–methanol should be preferred for extraction of all lipid and lipid oxidation‐derived molecules, including aldehydes.

Funder

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3