Identifying Slim Modiolar Electrode Tip Fold‐Over With Intracochlear Electrocochleography

Author:

Varghese Jordan J.1ORCID,Walia Amit1,Lefler Shannon M.1,Ortmann Amanda J.1,Shew Matthew A.1,Durakovic Nedim1,Wick Cameron C.1,Herzog Jacques A.1,Buchman Craig A.1

Affiliation:

1. Department of Otolaryngology–Head and Neck Surgery Washington University School of Medicine St. Louis Missouri USA

Abstract

AbstractObjectiveTo evaluate the predictive value of intracochlear electrocochleography (ECochG) for identifying tip fold‐over during cochlear implantation (CI) using the slim modiolar electrode (SME) array.Study DesignProspective cohort study.SettingTertiary referral center.MethodsFrom July 2022 to June 2023, 142 patients, including adults and children, underwent intracochlear ECochG monitoring during and after SME placement. Tone‐bursts were presented from 250 Hz to 2 kHz at 108 to 114 dB HL. A fast Fourier transform (FFT) allowed for frequency‐specific evaluation of ECochG response. ECochG patterns during insertion and postinsertion were evaluated using sensitivity and specificity analysis to predict tip fold‐over. Intraoperative plain radiographs served as a reference standard.ResultsFifteen tip fold‐over cases occurred (10.6%) with significant ECochG response (>2 µV). Sixty‐one cases without tip fold‐over occurred (43.0%) with significant ECochG response. All tip fold‐overs had both a nontonotopic postinsertion sweep and nonrobust active insertion pattern. No patients with robust insertion or tonotopic sweep patterns had tip fold‐over. Sensitivity of detecting tip fold‐over when having both nonrobust insertion and nontonotopic sweep patterns was 100% (95% confidence inteval [CI] 78.2%‐100%), specificity was 68.9% (95% CI 55.7%‐80.1%), and the overall accuracy was 72.0% (95% CI 60.5%‐81.7%).ConclusionIntracochlear ECochG monitoring during cochlear implantation with the SME can be a valuable tool for identifying properly positioned electrode arrays. In cases where ECochG patterns are nonrobust on insertion and nontonotopic for electrode sweeps, there may be a concern for tip fold‐over, and intraoperative imaging is necessary to confirm proper insertion.

Publisher

Wiley

Subject

Otorhinolaryngology,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3