Validating an Evoked Potential Platform for Electrocochleography During Cochlear Implantation

Author:

Varghese Jordan J.1ORCID,Shew Matthew A.1ORCID,Walia Amit1ORCID,Lefler Shannon M.1,Durakovic Nedim1ORCID,Wick Cameron C.1,Ortmann Amanda J.1,Herzog Jacques A.1ORCID,Buchman Craig A.1

Affiliation:

1. Department of Otolaryngology – Head and Neck Surgery Washington University School of Medicine St. Louis Missouri U.S.A.

Abstract

ObjectiveTo validate electrocochleography (ECochG) between an auditory evoked potential (AEP) machine and an established cochlear implant (CI) manufacturer ECochG system.MethodsIntraoperative validation study at a tertiary referral center. Patients included adults and children undergoing cochlear implantation. Intraoperative ECochG was measured with both the Intelligent Hearing Systems (IHS) Duet AEP machine and Cochlear Corporation (CC) ECochG platform. Recording electrodes captured extracochlear measurements through a standard facial recess. Tone‐bursts were presented from 250 Hz to 2 kHz (~110 dB SPL). A fast Fourier transform (FFT) of ECochG waveforms at key frequencies was summed into a total response (ECochG‐TR). Pearson's correlation was utilized to evaluate the relationship between IHS‐ECochG‐TR and CC‐ECochG‐TR after confirming normality.ResultsThirty patients were enrolled with an average age of 67 years (SD 18.8). In the ear that was implanted, mean preoperative pure‐tone average (PTA; 0.5, 1, 2, and 4 kHz) was 87.4 dB HL (SD 19.3) and mean preoperative word‐recognition scores (WRS) was 17.0% correct (SD 19.1). There was strong correlation (r = 0.905, 95% confidence interval: 0.809 to 0.954) between IHS‐ECochG‐TR (median 2.30 μV, range 0.1–148.26) and CC‐ECochG‐TR (median 3.00 μV, range 0.1–239.63). Four patients underwent transtympanic ECochG with the IHS system for feasibility evaluation and achieved similar responses.ConclusionExtracochlear ECochG has been predictive of CI speech perception performance. The IHS duet system is a valid measure of extracochlear ECochG for the CI population. Future work will utilize this system for measuring transtympanic ECochG to improve preoperative estimation of CI performance.Level of Evidence3 Laryngoscope, 2024

Funder

American Hearing Research Foundation

National Institute on Deafness and Other Communication Disorders

National Center for Advancing Translational Sciences

Publisher

Wiley

Reference33 articles.

1. Cochlear implantation in the world's largest medical device market: Utilization and awareness of cochlear implants in the United States

2. McMahonCM NiemanCL ThornePR EmmettSD BhuttaMF.The inaugural World Report on Hearing: From barriers to a platform for change. (1749–4486 (Electronic)).

3. BoisvertIA‐O ReisM AuA CowanR DowellRC.Cochlear implantation outcomes in adults: A scoping review. (1932–6203 (Electronic)).

4. Better speech recognition with cochlear implants

5. Cochlear Implantation in Adults

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3