Affiliation:
1. Keysight Laboratories Keysight Technologies Austria GmbH Linz 4020 Austria
Abstract
AbstractElectrochemical impedance spectroscopy (EIS) is widely used for battery cell testing in industrial production and R&D labs. This work addresses the use of EIS calibration and uncertainty analysis in cell classification. Five scenarios are investigated to discuss qualitatively the impact of calibration and uncertainty on classification. For an experimental demonstration, a cylindrical cell was measured with two mechanical fixtures of different qualities and characterized regarding random errors and calibrated impedances. The impact of uncertainty and impedance calibration on the cell classification is shown, and based on the uncertainty and corresponding error bounds, a confidence level was established for the classification results. Quantitative uncertainty bounds are presented for the full EIS frequency spectrum ranging from 150 mHz to 5 kHz.
Subject
Electrochemistry,Electrical and Electronic Engineering,Energy Engineering and Power Technology
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献