Towards quantitative digital subtraction perfusion angiography: An animal study

Author:

Su Ruisheng1,van der Sluijs P. Matthijs1,Bobi Joaquim2,Taha Aladdin2,van Beusekom Heleen M. M.2,van der Lugt Aad1,Niessen Wiro J.13,Ruijters Danny4,van Walsum Theo1

Affiliation:

1. Department of Radiology & Nuclear Medicine, Erasmus MC University Medical Center, Rotterdam The Netherlands

2. Department of Experimental Cardiology, Erasmus MC University Medical Center, Rotterdam The Netherlands

3. Faculty of Applied Sciences Delft University of Technology Delft The Netherlands

4. Philips Healthcare Best The Netherlands

Abstract

AbstractBackgroundX‐ray digital subtraction angiography (DSA) is the imaging modality for peri‐procedural guidance and treatment evaluation in (neuro‐) vascular interventions. Perfusion image construction from DSA, as a means of quantitatively depicting cerebral hemodynamics, has been shown feasible. However, the quantitative property of perfusion DSA has not been well studied.PurposeTo comparatively study the independence of deconvolution‐based perfusion DSA with respect to varying injection protocols, as well as its sensitivity to alterations in brain conditions.MethodsWe developed a deconvolution‐based algorithm to compute perfusion parametric images from DSA, including cerebral blood volume (CBV), cerebral blood flow (CBF), time to maximum (Tmax), and mean transit time (MTT) and applied it to DSA sequences obtained from two swine models. We also extracted the time intensity curve (TIC)‐derived parameters, that is, area under the curve (AUC), peak concentration of the curve, and the time to peak (TTP) from these sequences. Deconvolution‐based parameters were quantitatively compared to TIC‐derived parameters in terms of consistency upon variations in injection profile and time resolution of DSA, as well as sensitivity to alterations of cerebral condition.ResultsComparing to TIC‐derived parameters, the standard deviation (SD) of deconvolution‐based parameters (normalized with respect to the mean) are two to five times smaller, indicating that they are more consistent across different injection protocols and time resolutions. Upon ischemic stroke induced in a swine model, the sensitivities of deconvolution‐based parameters are equal to, if not higher than, those of TIC‐derived parameters.ConclusionsIn comparison to TIC‐derived parameters, deconvolution‐based perfusion imaging in DSA shows significantly higher quantitative reliability against variations in injection protocols across different time resolutions, and is sensitive to alterations in cerebral hemodynamics. The quantitative nature of perfusion angiography may allow for objective treatment assessment in neurovascular interventions.

Funder

Hartstichting

Publisher

Wiley

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3