A new sonoablation using acoustic droplet vaporization and focused ultrasound: A feasibility study

Author:

Li Hui1,He Huan1,Tang Jiawei1,Luo Tingting1,Yang Guoliang1,Huang Leidan2,Dong Xiaoxiao1,Liu Zheng1

Affiliation:

1. Department of Ultrasound The Second Affiliated Hospital of Army Medical University Chongqing China

2. Department of Ultrasound, Shenzhen Second People's Hospital The First Affiliated Hospital of Shenzhen University Shenzhen China

Abstract

AbstractBackgroundHistotripsy and boiling histotripsy are two methods of mechanical ablation that use high‐pressure focused ultrasound (FUS).PurposeHere, a new bubble sonoablation technique was investigated using low‐pressure FUS in combination with local injection of perfluoropentane (PFP) in rabbit liver.MethodsFifteen healthy New Zealand white rabbits were treated with FUS alone, FUS + PFP or PFP alone. FUS was performed using a single‐element focused transducer (frequency 596 kHz, 0.27 ms pulses, 0.54% duty cycle, and peak negative pressure 2.0 MPa). Ten minutes before FUS treatment, the PFP droplet was locally injected into the rabbit liver, where the ultrasound was focused. Contrast‐enhanced ultrasound (CEUS) of the liver was performed, and the temperature at the liver surface in the targeted liver region was recorded during treatment. The livers were collected for pathological examination. Statistical significance was set at p < 0.05. Paired t‐tests were used to compare the pre‐ and post‐treatment values. One‐way analysis of variance was performed to compare multiple groups, and the least significant difference method was used for further comparisons between the two groups.ResultsAnalysis of CEUS data showed that the values of area under the curve (AUC) were significantly different in the PFP + FUS group pre‐ (10453.644 ± 1182.93) and post‐treatment (4058.098 ± 2720.41), and the AUC values of PFP + FUS post‐treatment (4058.098 ± 2720.41) were also significantly lower than those of the FUS (9946.694 ± 1071.54) and the PFP (10364.794 ± 2181.53) groups. The peak intensity values also showed the same results, the value of peak intensity of PFP+FUS post‐treatment was 82.958 ± 13.99, whereas there was no difference between FUS (106.61 ± 7.61) and PFP (104.136 ± 10.55). Hematoxylin and eosin (H&E) staining revealed that the pathological damage ratings of the PFP + FUS, PFP, and FUS groups were grade 3, grade 1, and grade 0, respectively. Specifically, the area of liver necrosis in the PFP + FUS group (0.99 ± 0.29 cm2) was 198 times higher than that in the PFP group (0.005 ± 0.008 cm2), whereas no necrosis was observed in the livers treated with FUS alone. Simultaneously, the number of vacuoles in the liver of the PFP + FUS group (35.50 ± 23.31) was approximately five times that of the PFP group (7.00 ± 12.88), whereas no vacuoles were found in the liver treated with FUS alone.ConclusionPFP droplets combined with FUS can destroy liver tissue and cause tissue necrosis in the droplet injection area, without affecting the structure of surrounding tissue.

Funder

National Natural Science Foundation of China

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3