Interleaved trinuclear MRS for single‐session investigation of carbohydrate and lipid metabolism in human liver at 7T

Author:

Poli Simone123ORCID,Emara Ahmed F.4,Lange Naomi F.56ORCID,Ballabani Edona4,Buser Angeline4,Schiavon Michele7ORCID,Herzig David4ORCID,Man Chiara Dalla7ORCID,Bally Lia4ORCID,Kreis Roland12ORCID

Affiliation:

1. MR Methodology, Department for Diagnostic and Interventional Neuroradiology University of Bern Bern Switzerland

2. Translational Imaging Center (TIC) Swiss Institute for Translational and Entrepreneurial Medicine Bern Switzerland

3. Graduate School for Cellular and Biomedical Sciences University of Bern Bern Switzerland

4. Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism UDEM University Hospital Bern Bern Switzerland

5. Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital University of Bern Bern Switzerland

6. Graduate School for Health Sciences University of Bern Bern Switzerland

7. Department of Information Engineering (DEI) University of Padova Padua Italy

Abstract

AbstractThe liver plays a central role in metabolic homeostasis, as exemplified by a variety of clinical disorders with hepatic and systemic metabolic disarrays. Of particular interest are the complex interactions between lipid and carbohydrate metabolism in highly prevalent conditions such as obesity, diabetes, and fatty liver disease. Limited accessibility and the need for invasive procedures challenge direct investigations in humans. Hence, noninvasive dynamic evaluations of glycolytic flux and steady‐state assessments of lipid levels and composition are crucial for basic understanding and may open new avenues toward novel therapeutic targets. Here, three different MR spectroscopy (MRS) techniques that have been combined in a single interleaved examination in a 7T MR scanner are evaluated. 1H‐MRS and 13C‐MRS probe endogenous metabolites, while deuterium metabolic imaging (DMI) relies on administration of deuterated tracers, currently 2H‐labelled glucose, to map the spatial and temporal evolution of their metabolic fate. All three techniques have been optimized for a robust single‐session clinical investigation and applied in a preliminary study of healthy subjects. The use of a triple‐channel 1H/2H/13C RF coil enables interleaved examinations with no need for repositioning. Short‐echo‐time STEAM spectroscopy provides well resolved spectra to quantify lipid content and composition. The relative benefits of using water saturation versus metabolite cycling and types of respiratory synchronization were evaluated. 2H‐MR spectroscopic imaging allowed for registration of time‐ and space‐resolved glucose levels following oral ingestion of 2H‐glucose, while natural abundance 13C‐MRS of glycogen provides a dynamic measure of hepatic glucose storage. For DMI and 13C‐MRS, the measurement precision of the method was estimated to be about 0.2 and about 16 mM, respectively, for 5 min scanning periods. Excellent results were shown for the determination of dynamic uptake of glucose with DMI and lipid profiles with 1H‐MRS, while the determination of changes in glycogen levels by 13C‐MRS is also feasible but somewhat more limited by signal‐to‐noise ratio.

Funder

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Publisher

Wiley

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3