FLASH dose rate calculation based on log files in proton pencil beam scanning therapy

Author:

Jeon Chanil1,Ahn Sunghwan2,Amano Daizo3,Kamiguchi Nagaaki3,Cho Sungkoo2,Sheen Heesoon2,Park Hee Chul2,Han Youngyih12

Affiliation:

1. Department of Health Sciences and Technology SAIHST, Sungkyunkwan University Seoul Republic of Korea

2. Department of Radiation Oncology Samsung Medical Center Sungkyunkwan University School of Medicine Seoul Republic of Korea

3. Sumitomo Heavy Industries, Ltd Tokyo Japan

Abstract

AbstractBackgroundIn radiation therapy, irradiating healthy normal tissues in the beam trajectories is inevitable. This unnecessary dose means that patients undergoing treatment risk developing side effects. Recently, FLASH radiotherapy delivering ultra‐high‐dose‐rate beams has been re‐examined because of its normal‐tissue‐sparing effect. To confirm the mean and instantaneous dose rates of the FLASH beam, stable and accurate dosimetry is required.PurposeDetailed verification of the FLASH effect requires dosimeters and a method to measure the average and instantaneous dose rate stably for 2‐ or 3‐dimensional dose distributions. To verify the delivered FLASH beam, we utilized machine log files from the built‐in monitor chamber to develop a dosimetry method to calculate the dose and average/instantaneous dose rate distributions in two or three dimensions in a phantom.MethodsTo create a spread‐out Bragg peak (SOBP) and deliver a uniform dose in a target, a mini‐ridge filter was created with a 3D printer. Proton pencil beam line scanning plans of 2 × 2 cm2, 3 × 3 cm2, 4 × 4 cm2, and round shapes with 2.3 cm diameter patterns delivering 230 MeV energy protons were created. The absorbed dose in the solid water phantom of each plan was measured using a PPC05 ionization chamber (IBA Dosimetry, Virginia, USA) in the SOBP region, and the log files for each plan were exported from the treatment control system console. Using these log files, the delivered dose and average dose rate were calculated using two methods: a direct method and a Monte Carlo (MC) simulation method that uses log file information. The computed and average dose rates were compared with the ionization chamber measurements. Additionally, instantaneous dose rates in user‐defined volumes were calculated using the MC simulation method with a temporal resolution of 5 ms.ResultsCompared to ionization chamber dosimetry, 10 of 12 cases using the direct calculation method and 9 of 11 cases using the MC method had a dose difference below ±3%. Nine of 12 cases using the direct calculation method and 8 of 11 cases using the MC method had dose rate differences below ±3%. The average and maximum dose differences for the direct calculation and MC method were–0.17, +0.72%, and −3.15, +3.32%, respectively. For the dose rate difference, the average and maximum for the direct calculation and MC method were +1.26, +1.12%, and +3.75, +3.15%, respectively. In the instantaneous dose rate calculation with the MC simulation, a large fluctuation with a maximum of 163 Gy/s and a minimum of 4.29 Gy/s instantaneous dose rate was observed in a specific position, whereas the mean dose rate was 62 Gy/s.ConclusionsWe successfully developed methods in which machine log files are used to calculate the dose and the average and instantaneous dose rates for FLASH radiotherapy and demonstrated the feasibility of verifying the delivered FLASH beams.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3