Serum carcinoembryonic antigen trends for diagnosing colorectal cancer recurrence in the FACS randomized clinical trial

Author:

Shinkins B1ORCID,Primrose J N2,Pugh S A2,Nicholson B D3,Perera R3,James T4,Mant D3

Affiliation:

1. Test Evaluation Group, Academic Unit of Health Economics, University of Leeds, Leeds, UK

2. University Surgery, University of Southampton, Southampton, UK

3. Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK

4. Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK

Abstract

Abstract Background Most guidelines recommend that patients who have undergone curative resection for primary colorectal cancer are followed up for 5 years with regular blood carcinoembryonic antigen (CEA) tests to trigger further investigation for recurrence. However, CEA may miss recurrences, or patients may have false alarms and undergo unnecessary investigation. Methods The diagnostic accuracy of trends in CEA measurements for recurrent colorectal cancer, taken as part of the FACS (Follow-up After Colorectal Surgery) trial (2003–2014), were analysed. Investigation to detect recurrence was triggered by clinical symptoms, scheduled CT or colonoscopy, or a CEA level of at least 7 μg/l above baseline. Time-dependent receiver operating characteristic (ROC) curve analysis was used to compare the diagnostic accuracy of CEA trends with single measurements. CEA trends were estimated using linear regression. Results The area under the ROC curve (AUC) for CEA trend was at least 0·820 across all 5 years of follow-up. In comparison, the AUCs for single measurements ranged from 0·623 to 0·749. Improvement was most marked at the end of the first year of follow-up, with the AUC increasing from 0·623 (95 per cent c.i. 0·509 to 0·736) to 0·880 (0·814 to 0·947). However, no individual trend threshold achieved a sensitivity above 70 per cent (30 per cent missed recurrences). Conclusion Interpreting trends in CEA measurements instead of single CEA test results improves diagnostic accuracy for recurrence, but not sufficiently to warrant it being used as a single surveillance strategy to trigger further investigation. In the absence of a more accurate biomarker, monitoring trends in CEA should be combined with clinical, endoscopic and imaging surveillance for improved accuracy.

Funder

National Institute for Health Research (NIHR) cancer research networks

UK NIHR Technology Assessment (HTA) Programme

NIHR Leeds Diagnostic Evidence Co-operative

Publisher

Oxford University Press (OUP)

Subject

Surgery

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3