Intramodule pressure profiles and protein accumulation during tangential flow filtration

Author:

Cunha Fernanda12,Zuponcic Jessica12,Rossi Francesco3,Springer Grant12,Ximenes Eduardo12,Bruns Norvin4,Moomaw John F.5,Bowes Brian D.5,Qian Ken K.5,Yu Zhao5ORCID,Yang Dennis5,Corvari Vincent J.5,Ardekani Arezoo6,Reklaitis Gintaras3,Ladisch Michael124ORCID

Affiliation:

1. Department of Agricultural and Biological Engineering Purdue University West Lafayette Indiana USA

2. Laboratory of Renewable Resources Engineering Purdue University West Lafayette Indiana USA

3. Davidson School of Chemical Engineering Purdue University West Lafayette Indiana USA

4. Weldon School of Biomedical Engineering Purdue University West Lafayette Indiana USA

5. Bioproduct Research and Development Eli Lilly and Company Indianapolis Indiana USA

6. School of Mechanical Engineering Purdue University West Lafayette Indiana USA

Abstract

AbstractTangential flow filtration (TFF) through a 30 kDa nominal molecular weight cut‐off (MWCO) ultrafiltration membrane is widely employed to concentrate purified monoclonal antibodies (mAbs) to levels required for their formulation into injectable biologics. While TFF has been used to remove casein from milk for cheese production for over 35 years, and in pharmaceutical manufacture of biotherapeutic proteins for 20 years, the rapid decline in filtration rate (i.e., flux) at high protein concentrations is a limitation that still needs to be addressed. This is particularly important for mAbs, many of which are 140–160 kDa immunoglobulin G (IgG) type proteins recovered at concentrations of 200 mg/mL or higher. This work reports the direct measurement of local transmembrane pressure drops and off‐line confocal imaging of protein accumulation in stagnant regions on the surface of a 30 kDa regenerated cellulose membrane in a flat‐sheet configuration widely used in manufacture of biotherapeutic proteins. These first‐of‐a‐kind measurements using 150 kDa bovine IgG show that while axial pressure decreases by 58 psi across a process membrane cassette, the decrease in transmembrane pressure drop is constant at about 1.2 psi/cm along the 20.7 cm length of the membrane. Confocal laser scanning microscopy of the membrane surface at the completion of runs where retentate protein concentration exceeds 200 mg/mL, shows a 50 μm thick protein layer is uniformly deposited. The localized measurements made possible by the modified membrane system confirm the role of protein deposition on limiting ultrafiltration rate and indicate possible targets for improving membrane performance.

Publisher

Wiley

Subject

Biotechnology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3