Development of a digital star‐shot analysis system for comparing radiation and imaging isocenters of proton treatment machine

Author:

Han Ji Hye1ORCID,Jo Kwanghyun2ORCID

Affiliation:

1. Department of Physics Ewha Womans University Seoul South Korea

2. Department of Radiation Oncology Samsung Medical Center Seoul South Korea

Abstract

AbstractPurposeTo directly compare the radiation and imaging isocenters of a proton treatment machine, we developed and evaluated a real‐time radiation isocenter verification system.MethodsThe system consists of a plastic scintillator (PI‐200, Mitsubishi Chemical Corporation, Tokyo, Japan), an acrylic phantom, a steel ball on the detachable plate, Raspberry Pi 4 (Raspberry Pi Foundation, London, UK) with camera module, and analysis software implemented through a Python‐based graphical user interface (GUI). After kV imaging alignment of the steel ball, the imaging isocenter defined as the position of the steel ball was extracted from the optical image. The proton star‐shot was obtained by optical camera because the scintillator converted proton beam into visible light. Then the software computed both the minimum circle radius and the radiation isocenter position from the star‐shot. And the deviation between the imaging isocenter and radiation isocenter was calculated. We compared our results with measurements obtained by Gafchromic EBT3 film (Ashland, NJ, USA).ResultsThe minimum circle radii were averaged 0.29 and 0.41 mm while the position deviations from the radiation isocenter to the laser marker were averaged 0.99 and 1.07 mm, for our system and EBT3 film, respectively. Furthermore, the average position difference between the radiation isocenter and imaging isocenter was 0.27 mm for our system. Our system reduced analysis time by 10 min.ConclusionsOur system provided automated star‐shot analysis with sufficient accuracy, and it is cost‐effective alternative to conventional film‐based method for radiation isocenter verification.

Funder

National Research Foundation of Korea

Publisher

Wiley

Reference34 articles.

1. Task Group 142 report: Quality assurance of medical acceleratorsa)

2. AAPM task group 224: Comprehensive proton therapy machine quality assurance

3. A procedure to determine the radiation isocenter size in a linear accelerator

4. Development of a method to measure the radiation isocenter size of linear accelerators and quantitative analysis of the radiation isocenter size for clinac 21EX linear accelerator;Jeon HS;Prog Med Phys,2011

5. Computer-aided analysis of star shot films for high-accuracy radiation therapy treatment units

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3