AbstractBackgroundIntensity‐modulated proton therapy (IMPT) is a well‐known delivery method of proton therapy. Besides higher plan quality, reducing the delivery time is also essential to IMPT plans. It can enhance patient comfort, reduce treatment costs, and improve delivery efficiency. From the perspective of treatment efficacy, it contributes to mitigating the intra‐fractional motions and improving the accuracy of radiotherapy, especially for moving tumors.PurposeHowever, there is a tradeoff problem between the plan quality and delivery time. We consider the potential of a large momentum acceptance (LMA) beamline and apply the spots and energy layers reduction method to reduce the delivery time.MethodsThe delivery time for each field consists of the energy layer switching time, spot traveling time, and dose delivery time. The larger momentum spread and higher intensity beam offered by the LMA beamline contribute to reducing the total delivery time compared to the conventional beamline. In addition to the dose fidelity term, an L1 and logarithm items were added to the objective function to increase the sparsity of the low‐weighted spots and energy layers. After that, the low‐weighted spots and layers were iteratively excluded in the reduced plan, which reduced the energy layer switching time and spot traveling time. We used the standard, reduced, and LMA‐reduced plans to validate the proposed method and tested it on prostate and nasopharyngeal cases. Then, we compared and evaluated the plan quality, treatment time, and plan robustness against delivery uncertainty.ResultsCompared with the standard plans, the number of spots in the LMA‐reduced plans was on average reduced by 13 400 (95.6%) for prostate cases and by 48 300 (80.7%) for nasopharyngeal cases and the number of energy layers was on average reduced by 49 (61.3%) for prostate cases and by 97 (50.5%) for nasopharyngeal cases. And, the delivery time of the LMA‐reduced plans was shortened from 34.5 to 8.6 s for prostate cases and from 163.8 to 53.6 s for nasopharyngeal cases. The LMA‐reduced plans had comparable robustness to the spot monitor unit (MU) error compared with the standard plans, but the LMA‐reduced plans became more sensitive to spot position uncertainty.ConclusionThe delivery efficiency can be significantly improved using the LMA beamline and spots and energy layers reduction strategies. The method is promising to improve the efficiency of motion mitigation strategies for treating moving tumors.
Funder
National Natural Science Foundation of China
National Key Research and Development Program of China
Fundamental Research Funds for the Central Universities
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献