Efficiency of High and Standard b Value Diffusion-Weighted Magnetic Resonance Imaging in Grading of Gliomas

Author:

Al-Agha Mansour1ORCID,Abushab Khaled2,Quffa Khetam2,Al-Agha Samy2,Alajerami Yasser2,Tabash Mohammed2ORCID

Affiliation:

1. Radiology Department, Al-Shifa Medical Complex, Ministry of Health, Gaza, State of Palestine

2. Medical Imaging Department, Faculty of Applied Medical Sciences, Al Azhar University-Gaza, Gaza, State of Palestine

Abstract

Background. Glioma is the most common fatal malignant tumor of the CNS. Early detection of glioma grades based on diffusion-weighted imaging (DWI) properties is considered one of the most recent noninvasive promising tools in the assessment of glioma grade and could be helpful in monitoring patient prognosis and response to therapy. Aim. This study aimed to investigate the accuracy of DWI at both standard and high b values (b = 1000 s/mm2 and b = 3000 s/mm2) to distinguish high-grade glioma (HGG) from low-grade glioma (LGG) in clinical practice based on histopathological results. Materials and Methods. Twenty-three patients with glioma had DWI at l.5 T MR using two different b values (b = 1000 s/mm2 and b = 3000 s/mm2) at Al-Shifa Medical Complex after obtaining ethical and administrative approvals, and data were collected from March 2019 to March 2020. Minimum, maximum, and mean of apparent diffusion coefficient (ADC) values were measured through drawing region of interest (ROI) on a solid part at ADC maps. Data were analyzed by using the MedCalc analysis program, version 19.0.4, receiver operating characteristic (ROC) curve analysis was done, and optimal cutoff values for grading gliomas were determined. Sensitivity and specificity were also calculated. Results. The obtained results showed the ADCmean, ADCratio, ADCmax, and ADCmin were performed to differentiate between LGG and HGG at both standard and high b values. Moreover, ADC values were inversely proportional to glioma grade, and these differences are more obvious at high b value. Minimum ADC values using standard b value were 1.13 ± 0.17 × 10−3 mm2/s, 0.89 ± 0.85 × 10−3 mm2/s, and 0.82 ± 0.17 × 10−3 mm2/s for grades II, III, and IV, respectively. Concerning high b value, ADCmin values were 0.76 ± 0.07 × 10−3 mm2/s, 0.61 ± 0.01 × 10−3 mm2/s, and 0.48 ± 0.07 × 10−3 mm2/s for grades II, III, and IV, respectively. ADC values were inversely correlated with results of glioma grades, and the correlation was stronger at ADC3000 (r = −0.722, P0.001). The ADC3000 achieved the highest diagnostic accuracy with an area under the curve (AUC) of 0.618, 100% sensitivity, 85.7% specificity, and 85.7% accuracy for glioma grading at a cutoff point of ≤0.618 × 10−3 mm2/s. The high b value showed stronger agreement with histopathology compared with standard b value results (k = 0.89 and 0.79), respectively. Conclusion. The ADC values decrease with an increase in tumor cellularity. Meanwhile, high b value provides better tissue contrast by reflecting more tissue diffusivity. Therefore, ADC-derived parameters at high b value are more useful in the grading of glioma than those obtained at standard b value. They might be a better surrogate imaging sequence in the preoperative evaluation of gliomas.

Publisher

Hindawi Limited

Subject

Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3