Biomechanical Characteristics of Three Baseplate Rotational Arrangement Techniques in Total Knee Arthroplasty

Author:

Kang KwanSu1ORCID,Jang Young Woong2,Yoo Oui Sik2,Jung Dukyoung3,Lee Sung-Jae4,Lee Myung Chul5,Lim Dohyung1ORCID

Affiliation:

1. Department of Mechanical Engineering, Sejong University, Seoul, Republic of Korea

2. Central R&D Center, Corentec Co. Ltd., Seoul, Republic of Korea

3. Seongnam Senior Experience Complex, Eulji University, Seongnam, Republic of Korea

4. Department of Biomedical Engineering, Inje University, Gimhae, Republic of Korea

5. Department of Orthopedic Surgery, College of Medicine, Seoul National University, Seoul, Republic of Korea

Abstract

Introduction. Several ongoing studies aim to improve the survival rate following total knee arthroplasty (TKA), which is an effective orthopedic surgical approach for patients with severely painful knee joint diseases. Among the studied strategies, baseplate rotational arrangement techniques for TKA components have been suggested but have been the subject of only simple reliability evaluations. Therefore, this study sought to evaluate comparatively three different baseplate rotational arrangement techniques that are commonly used in a clinical context. Materials and Methods. Three-dimensional (3D) finite element (FE) models of the proximal tibia with TKA were developed and analyzed considering three baseplate rotational arrangement techniques (anterior cortex line, tibial tuberosity one-third line, and tibial tuberosity end line) for six activities of daily life (ADLs) among patients undergoing TKA. Mechanical tests based on the ASTM F1800 standard to validate the FE models were then performed using a universal testing machine. To evaluate differences in biomechanical characteristics according to baseplate rotational arrangement technique, the strain and peak von Mises stresses (PVMSs) were assessed. Results. The accuracy of the FE models used in this study was high (94.7 ± 5.6%). For the tibial tuberosity one-third line rotational arrangement technique, strains ≤ 50 µstrain (the critical bone damage strain, which may affect bone remodeling) accounted for approximately 2.2%–11.3% and PVMSs within the bone cement ranged from 19.4 to 29.2 MPa, in ADLs with high loading conditions. For the tibial tuberosity end line rotational arrangement, strains ≤ 50 µstrain accounted for approximately 2.3%–13.3% and PVMSs within the bone cement ranged from 13.5 to 26.7 MPa. For anterior cortex line rotational arrangement techniques, strains ≤50 µstrain accounted for approximately 10.6%–16.6% and PVMSs within the bone cement ranged from 11.6 to 21.7 MPa. Conclusion. The results show that the most recently developed frontal cortex line rotational alignment technique is the same or better than the other two rotational alignment techniques in terms of biomechanics. This finding can be, however, dependent on the contact characteristics between the baseplate and the proximal tibia. That is, it is indicated that the optimum baseplate rotational arrangement technique in terms of reducing the incidence of TKA mechanical failure can be achieved by adjusting the characteristics of contact between the baseplate and the proximal tibia.

Funder

Ministry of Science, ICT and Future Planning

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine