Numerical Study on the Thermal Performance of Trombe Wall for Passive Solar Building in Semiarid Climate

Author:

Dhahri Maher12ORCID,Khalilpoor Nima3ORCID,Aouinet Hana4,Issakhov Alibek5ORCID,Sammouda Habib2,Emani Sampath6

Affiliation:

1. Higher Institute of Agricultural Sciences of Chott Mariem, University of Sousse, BP No. 47, 4042 Sousse, Tunisia

2. Laboratory of Energy and Materials (LabEM) (LR11ES34), High School of Sciences and Technology of Hammam Sousse, Sousse University, BP, 4011 Hammam Sousse, Tunisia

3. Department of Energy Engineering, Graduate School of the Environment and Energy, Science and Research Branch, Islamic Azad University, Tehran, Iran

4. Higher Private School of Engineering and Applied Techniques (IHE-ESPITA), Sousse, Tunisia

5. Faculty of Mechanics and Mathematics, Department of Mathematical and Computer Modelling, Al-Farabi Kazakh National University, Almaty, Kazakhstan

6. Chemical Engineering Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, Perak D.R., Malaysia

Abstract

The largest amount of energy in buildings is consumed to provide heating, cooling, and ventilation. Therefore, a practical solution such as using renewable energy sources can be considered to reduce energy costs and pollutants. In addition, architecture principles must be varied to utilize passive solar energy and also to reduce energy losses. In this research, a numerical study is presented to investigate the thermal behavior of TW-FR (Trombe wall placed in a fenestrated room) in the semiarid region of Tunisia. Computational fluid dynamic (CFD) simulation of fluid flow and heat transfer shows good agreement with published data in literature. The thermal comfort level was calculated according to ASHRAE (55-2013). The results show that (i) the normal Trombe wall cannot assure a satisfactory comfort level even in summer conditions and a higher vertical temperature gradient can take a value of 15°C, and the Trombe wall is shown to be more efficient in heating mode in the studied semi-arid region compared to cooling; (ii) the operative temperature for the coldest winter is between 17.85 and 19.85°C. The air temperature gradient in the comfort ranges between the head and feet is 2.3°C; and (iii) the Trombe wall is an excellent solution for Sousse city weather; it is suggested that the passive system (TW-FR) will be examined for a whole year to have a precise evaluation of its efficiency.

Publisher

Hindawi Limited

Subject

General Materials Science,Renewable Energy, Sustainability and the Environment,Atomic and Molecular Physics, and Optics,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3