Abstract

Toward conducting clinical pharmacokinetic studies of an antineoplastic agent, lenvatinib, we developed a liquid chromatography-tandem mass spectrometric assay for its quantitative analysis in human plasma. Analyte (lenvatinib) and internal standard (IS, propranolol) in the plasma were extracted by using acetonitrile and chromatographically separated by using a XTerra MS C18 column with 0.2 mL/min flow and mobile phase starting with 0.1% formic acid in water, followed by increasing percentage of acetonitrile. Detection was performed by using combined reversed-phase liquid chromatography-tandem mass spectrometry (LC/MS-MS) with positive ion electrospray ionization. MS-MS ion transitions used were 427.602>371.000 for lenvatinib and 260.064>116.005 for IS. This study was validated for accuracy, precision, linearity, range, selectivity, lower limit of quantification, recovery, and matrix effect according to the Guideline on Bioanalytical Method Validation in Pharmaceutical Development in Japan. Calibration curve was plotted by using lenvatinib concentrations ranging within 9.6–200 ng/mL, and correlation coefficients (r2) were in excess of 0.997. Intra- and interday accuracy ranged within 95.8–108.3% with mean recoveries of 66.8% for lenvatinib, and precision was <6.7% at all quality control concentration levels. Matrix effect analysis showed extraction efficiency of 15.7% for lenvatinib. Collectively, these findings demonstrate the feasibility of this method to evaluate kinetic disposition of lenvatinib.

Funder

Foundation for Promotion of Cancer Research

Publisher

Hindawi Limited

Subject

Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3