Corneal and Epithelial Thickness Mapping: Comparison of Enhanced Spectral-Domain- and Spectral-Domain-Optical Coherence Tomography

Author:

Georgeon Cristina1ORCID,Marciano Ilanite1,Cuyaubère Roxane1,Sandali Otman1ORCID,Bouheraoua Nacim1ORCID,Borderie Vincent1ORCID

Affiliation:

1. GRC 32,Transplantation et Thérapies Innovantes de La Cornée, Sorbonne Université, Centre Hospitalier National D’Ophtalmologie des Quinze-Vingts, Paris, France

Abstract

Objective. To compare the results and repeatability of the corneal thickness (CT) and epithelial thickness (ET) maps provided by Enhanced Spectral-Domain-Optical Coherence Tomography with those of Spectral-Domain-OCT in normal eyes. Methods. 30 normal eyes of 30 patients were assessed by 3 trained operators with ESD-OCT and SD-OCT. Results. The central and minimum ET obtained with both devices were correlated: central ET, r = 0.86, p < 0.05 ; minimum ET, r = 0.72, p < 0.05 . Compared with SD-OCT, ESD-OCT tended to underestimate these figures by 1.4 and 1.9 μm on average. The central and minimum CT obtained with both devices were strongly correlated: central CT, r = 0.994, p < 0.05 ; minimum CT, r = 0.995, p < 0.05 . ESD-OCT tended to overestimate these figures by 11 and 14 μm on average. Repeatability was good for both devices with a mean coefficient of variation of measurements <6% for ET and <2% for CT. Interoperator variability (standard deviation and COV) was significantly higher for ESD-OCT than for SD-OCT for all local epithelial thicknesses and significantly lower for the central CT and several local corneal thicknesses, whereas no significant differences between both technologies were found for the central and minimum ET and the minimum CT. Conclusion. ESD-OCT and SD-OCT provide reproducible measurements of CT and ET in normal corneas with a strong correlation between both technologies. However, both technologies are not interchangeable when the main thickness parameters (i.e., central and minimum CT and minimum ET) are used for diagnosing early keratoconus or calculating the expected residual stromal bed thickness before corneal refractive surgery or anterior lamellar keratoplasty.

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3