Cost-Effectiveness and Validity Assessment of Cyscope Microscope, Quantitative Buffy Coat Microscope, and Rapid Diagnostic Kit for Malaria Diagnosis among Clinic Attendees in Ibadan, Nigeria

Author:

Ogunniyi Abiodun123ORCID,Dairo Magbagbeola David3ORCID,Dada-Adegbola Hannah2,Ajayi Ikeoluwapo O.13,Olayinka Adebola14,Oyibo Wellington A.5,Fawole Olufunmilayo I.13,Ajumobi Olufemi16ORCID

Affiliation:

1. Nigeria Field Epidemiology and Laboratory Training Program, Abuja 900231, Nigeria

2. Department of Medical Microbiology, University College Hospital, Ibadan 200281, Nigeria

3. Department of Epidemiology and Medical Statistics, College of Medicine, University of Ibadan, Ibadan 200281, Nigeria

4. Department of Medical Microbiology, Ahmadu Bello University, Zaria 810105, Nigeria

5. Department of Medical Microbiology, College of Medicine, University of Lagos, Lagos 100283, Nigeria

6. National Malaria Elimination Program, Federal Ministry of Health, Abuja 900211, Nigeria

Abstract

Background. Unavailability of accurate, rapid, reliable, and cost-effective malaria diagnostic instruments constitutes major a challenge to malaria elimination. We validated alternative malaria diagnostic instruments and assessed their comparative cost-effectiveness. Method. Using a cross-sectional study design, 502 patients with malaria symptoms at selected health facilities in Ibadan between January and April 2014 were recruited consecutively. We examined malaria parasites using Cyscope®, QBC, and CareStart and results were compared to light microscopy (LM). Validity was determined by assessing sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Costs per hour of use for instruments and turnaround time were determined. Result. Sensitivity of the instruments was 76.0% (CareStart), 95.0% (Cyscope), and 98.1% (QBC). Specificity was 96.0% (CareStart), 87.3% (Cyscope), and 85.5% (QBC). PPV were 65.2%, 67.5%, and 84.7%, while NPV were 93.6%, 98.6%, and 99.4% for CareStart, Cyscope, and QBC with Kappa values of 0.75 (CI = 0.68–0.82) for CareStart, 0.72 (CI = 0.65–0.78) for Cyscope, and 0.71 (CI = 0.64–0.77) for QBC. Average cost per hour of use was the lowest ($2.04) with the Cyscope. Turnaround time was the fastest with Cyscope (5 minutes). Conclusion. Cyscope fluorescent microscope had the shortest turnaround time and is the most cost-effective of all the malaria diagnostic instruments evaluated.

Funder

Centers for Disease Control and Prevention

Publisher

Hindawi Limited

Subject

Infectious Diseases,Epidemiology