Abstract
Introduction. Magnetic Resonance Imaging has better resolution for soft tissue; at the same time, the robot can work in a stable manner for a long time. MRI image-guided breast interventional robots have attracted much attention due to their minimally invasive nature and accuracy. In this paper, a hydraulic-driven MRI-compatible breast interventional robot is proposed to perform breast interventional procedure. Methods. First is the analysis of the design requirements of the hydraulic-driven MRI-compatible breast interventional robot, and then the design scheme is determined. Second, the three-dimensional model and the link frames are established. The workspace of the robot end point is solved by MATLAB/Simulink software. Then, the 3D printing technology is used to make a physical model of the MRI-compatible breast interventional robot. After assembly and debugging, the physical model is used for workspace verification, and the simulation result of the workspace shows that it is correct. Finally, the experimental research on the positioning error of the hydraulic drive is carried out, which established the theoretical foundation for the follow-up control research of the robot. Results. The positioning error has nothing to do with the motion distance, speed, and length of the selected tubing. The errors are 0.564 mm, 0.534 mm, and 0.533 mm at different distances of 40 mm, 80 mm, and 120 mm, respectively. The errors are 0.552 mm, 0.564 mm, and 0.559 mm at different speeds of 3 mm/s, 5 mm/s, and 8 mm/s, respectively. The errors are 0.564 mm, 0.568 mm, and 0.548 mm for different lengths of 0.5 m, 1 m, and 1.6 m, respectively. Then, the robot’s working space on the
plane and the
plane meets the conditions. Conclusion. The structure of a differential rotary breast interventional robot is determined, with the link frames assigned to the mechanism and the Denavit-Hartenberg parameters given. Workspace simulation of MRI-compatible breast interventional robot is done in MATLAB. The 3D printed MRI-compatible breast interventional robot is assembled and debugged to verify that its working space and positioning error meet the requirements.
Funder
Natural Science Foundation of Heilongjiang Province
Subject
Biomedical Engineering,Bioengineering,Medicine (miscellaneous),Biotechnology
Reference28 articles.
1. Incidence and mortality of female breast cancer in China—a report from 32 Chinese cancer registries, 2003-2007;Z. Z. Huang;Tumor,2012
2. Segmentation of breast ultrasound image with semantic classification of superpixels
3. To evaluate the role of sonography as an adjunct to mammography in women with dense breasts;I. Masroor;Journal of the Pakistan Medical Association,2009
4. Contrast-enhanced MR imaging of breast lesions and effect on treatment
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. A review of robot‐assisted ultrasound examination: Systems and technology;The International Journal of Medical Robotics and Computer Assisted Surgery;2024-07-08
2. Research on Path Planning of Breast Ultrasound Examination Robot *;2023 IEEE International Conference on Robotics and Biomimetics (ROBIO);2023-12-04
3. A Decade of MRI Compatible Robots: Systematic Review;IEEE Transactions on Robotics;2023-04
4. Breast intervention surgery robot under image navigation: A review;Advances in Mechanical Engineering;2021-06