Affiliation:
1. School of Hydraulic, Energy and Power Engineering, Yangzhou University, Yangzhou 225127, China
2. Jiangsu Surveying & Design Institute of Water Resources Co. Ltd., Yangzhou 225127, China
Abstract
Aiming at the performance defect of tubular pump with fixed guide vanes, a design scheme of tubular pump with adjustable guide vanes is proposed, so that the inlet setting angle of guide vanes can be flexibly adjusted to coordinate with the operation conditions of pump, to ensure the inlet setting angle of guide vanes changing with the outlet flow angle of the impeller. The three-dimensional time-averaged incompressible Navier-Stokes equations are adopted to numerically simulate the internal flow field of a tubular pump with fixed and adjustable guide vanes, respectively. Computed results indicate that with the design of adjustable guide vanes and at off-design flow rates the flow conditions inside the diffuser of tubular pump can be improved effectively, and its hydraulic losses can be reduced. When the impeller blade angles are fixed the best efficiency points are within 0.51% while adjusting setting angles of guide vanes within a certain range. Under off-design conditions the hydraulic efficiency of tubular pump with adjustable guide vanes can be obviously improved by 1.70% at 0.75 Q0 and 2.19% at 1.20 Q0, when the blade angle is 0 degrees and the angle of guide vanes is adjusted to be 2 degrees smaller and larger, respectively.
Funder
China’s National Scientific Support Scheme
Cited by
6 articles.
订阅此论文施引文献