Reliability of Chest Wall Mobility and Its Correlation with Lung Functions in Healthy Nonsmokers, Healthy Smokers, and Patients with COPD

Author:

Reddy Ravi S.1ORCID,Alahmari Khalid A.1ORCID,Silvian Paul S.1ORCID,Ahmad Irshad A.1ORCID,Kakarparthi Venkata Nagaraj1ORCID,Rengaramanujam Kanagaraj1ORCID

Affiliation:

1. Department of Medical Rehabilitation, King Khalid University, Abha 61421, Saudi Arabia

Abstract

Chest wall circumference measurements are common evaluation methods in clinical settings by therapists in order to obtain chest wall mobility. Previous published results have been conflicting, and there is a lot of variability in the method of testing, which needs testing in different conditions. Seventy subjects (25 healthy nonsmokers, 25 healthy smokers, and 20 COPD) aged between 18 and 70 years participated in the study. Upper and lower chest expansion (CE) measurements (2 levels) are performed with cloth inch tape. Intrarater (between day) and interrater (within-day) reliability of CE measurements was evaluated by two examiners. Lung function parameters, forced expiratory volume in first second (FEV1), forced vital capacity (FVC), FEV1/FVC, and vital capacity (VC) were measured using a computerized spirometer (Spiro lab 3). The intrarater reliability for upper and lower CE showed very good agreement with intraclass correlation (ICC) values between 0.90 and 0.93 for upper CE and 0.85 to 0.86 for lower CE. The interrater reliability for upper CE showed good to very good agreement with ICC values ranging between 0.78 and 0.83, and lower CE showed very good agreement with ICC values ranging between 0.82 and 0.84. Upper and lower CE showed a significant and positive correlation with all lung function parameters, with strong correlation with FEV1/FVC (r = 0.68). Upper and lower CE measurements with inch tape showed good intra- and interrater reliability and reproducibility in healthy nonsmokers, healthy smokers, and COPD subjects. Compared to upper, lower CE correlated well with the lung function parameters. Upper and lower CE may be more useful in clinical practice to evaluate chest mobility and to give indirect information on lung function but interpretation with caution is required when considering implementation into clinical setting.

Funder

King Khalid University

Publisher

Hindawi Limited

Subject

Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3