Numerical Simulation of Galvanic Corrosion between Carbon Steel and Low Alloy Steel in a Bolted Joint

Author:

Radouani Rachid1ORCID,Echcharqy Younes1,Essahli Mohamed1

Affiliation:

1. Laboratory of Applied Chemistry and Environment, Faculty of Science and Technology, University of Hassan 1, Settat, Morocco

Abstract

The galvanic corrosion of a bolt joint combining carbon steel end plate and low alloy steel bolt was investigated electrochemically in a 1 M HCl solution. The corrosion parameters of the joint components were used for numerical simulation using Comsol Multiphysics software to analyze the galvanic corrosion behavior at the contact zone between the head bolt and the end plate. In this research work we evaluate the variation of the corrosion rate in the steel end plate considered as the anode, in order to determine the lifetime of the bolted assembly used in steel structures. Three materials (20MnCr5, 42CrMo4, and 32CrMoV13) and three bolts (M12, M16, and M20) were tested in two thicknesses of electrolyte 1 M HCl (e = 1 mm, e = 20 mm). It is found that the corrosion rate of the anode part (end plate) is higher for 32CrMoV13 materials and it increases if both diameter of the bolt and thickness of the electrolyte increase (Cr(M20) > Cr(M16) > Cr(M12) and Cr(e = 20 mm) > Cr(e = 1 mm)). This corrosion rate is higher in the contact area between the bolt head and the end plate, and it decreases if we move away from this contact area.

Publisher

Hindawi Limited

Subject

Process Chemistry and Technology,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3