Different Harmonic Characteristics Were Found at Each Location on TCM Radial Pulse Diagnosis by Spectrum Analysis

Author:

Tsai Yun-Ning123,Huang Yi-Chia13ORCID,Lin Sunny Jui-Shan34,Lee Shen-Ming56ORCID,Cheng Yung-Yen7ORCID,Chang Yu-Hsin8ORCID,Su Yi-Chang149ORCID

Affiliation:

1. Graduate Institute of Chinese Medicine, College of Chinese Medicine, China Medical University, Taichung 40402, Taiwan

2. Chander Clinic, Taipei 10646, Taiwan

3. Department of Chinese Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 11490, Taiwan

4. National Research Institute of Chinese Medicine, Ministry of Health and Welfare, Taipei 11221, Taiwan

5. Department of Statistics, Feng-Chia University, Taichung 40764, Taiwan

6. Center for Survey Research, Research Center for Humanities and Social Sciences, Academia Sinica, Taipei 11529, Taiwan

7. The Department of Internal Medicine, Nantou Hospital of the Ministry of Health and Welfare, Nantou 54062, Taiwan

8. Taichung Chander Clinic, Taichung 40356, Taiwan

9. School of Chinese Medicine, College of Chinese Medicine, China Medical University, Taichung 40402, Taiwan

Abstract

Purpose. This study aimed to clarify whether it is appropriate to choose any measurement location for pulse diagnosis research. Methods. A total of 37 subjects were recruited and measured for pulse pressure waves at 18 locations (9 per hand of “three positions and nine indicators”). These data were Fourier-transformed to the frequency spectrum, and the harmonics of C0-C10 of each location were obtained. Box plots of the harmonics were generated using SPSS v.22.0 and R v.3.4.1. Data were compared with multivariate analysis of variance (MANOVA) with a randomized block design. Results. The results showed that certain harmonics were different at different positions and different indicators; the harmonics of the same indicator at different positions (except for C8 and C10) and those of different indicators for the same position (except for C4 and C5) were significantly different (p<0.05). Conclusions. In future researches of pulse diagnosis, due to the significant differences between positions and indicators, it is recommended that the measurement position should be carefully chosen instead of choosing any measurement location to ensure the integrity of the acquired information for further analyzing physiological or pathological status.

Funder

Committee on Chinese Medicine and Pharmacy, Department of Health

Publisher

Hindawi Limited

Subject

Complementary and alternative medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3